ICM Controls Gas Ignition Control Board
ICM292
Categories
Description
Gas Ignition Control Board - replacement for Rheem 62-24140-04 control boards. Specifications: Control Voltage: 24 VAC (18-30 VAC), 60Hz Line Voltage: 115 VAC, 60Hz Timing: Pre-Purge: 30 seconds Trial for Ignition: 7 seconds Retries: Two groups of two, 30 second delay within the group, and 3 minute delay between groups Lockout: 1-hour Post-Purge: 90, 120, 160 and 180 seconds Inputs: Power: 24 VAC and COM Thermostat Interface: R,W, Y, and G System Switches: Vent pressure and limit switches (main and over-temperature switches in series) Flame Sensing Heat Blower OFF Delay (miniature slide switch set) Outputs: Spark Gas Valve: GV Inducer Draft Motor: IDM Blower Motor: FAN, COOL and HEAT speeds Electric air Cleaner: EAC Humidifier Relay: HUM Heat/Cool Relay: H/C LED Indicators: Power, Green LED: PWR Status, Green LED: OK Flame Status, Yellow LED: FLAME Patents: #6,222,719: Ignition Boost #5,917,691: Fail Safe Relay Driver
Manuals
# | Title | Languages | Pages | Updated |
---|---|---|---|---|
1 | Product Overview | EN | 1 | 2022-03-23 |
2 | User Guide | EN | 2 | 2022-03-23 |