5 Troubleshooting 
Problem Corrective Action
None of the 
LEDs turn 
on.
Check all cable connections.
Make sure that you have the USB or the power adaptor 
connected to the ZyWALL and plugged in to an appropriate 
power source. 
Note: Do NOT connect the USB and the PWR ports at 
the same time. This will damage your ZyWALL. 
If supplying power via the USB port, use only the included 
USB cable. 
Power to the ZyWALL is too low. Disconnect the USB cable 
from the ZyWALL and connect the power adaptor. 
If the LEDs still do not turn on, you may have a hardware 
problem. In this case, you should contact your local vendor.
All LEDs 
blink at the 
same time. 
Power to the ZyWALL is too low. Disconnect the USB cable 
from the ZyWALL and connect the power adaptor. 
Cannot 
access the 
ZyWALL 
from the 
LAN.
Check the cable connection between the ZyWALL and your 
computer. 
Ping the ZyWALL from a LAN computer. Make sure your 
computer’s Ethernet card is installed and functioning properly.
Verify that the IP addresses and subnet masks of the ZyWALL 
and you computer are in the same range. 