User`s manual
P-660 Series Support Notes
160
All contents copyright © 2005 ZyXEL Communications Corporation.
• To download the SMT configuration, please get the remote file 'rom-0' from
the Prestige.
• To upload the SMT configuration, please save the remote file as 'rom-0' in the
Prestige.
An example:
The 192.168.1.1 is the IP address of the Prestige.
The local file is the source file of your configuration file that is available in
your hard disk.
The remote file is the file name that will be saved in Prestige.
Check the port number 69 and 512-Octet blocks for TFTP.
Check 'Binary' mode for file transfering.
Using TFTP command on Windows NT
Before you begin:
1. TELNET to your Prestige first before using TFTP command
2. Type the CI command 'sys stdio 0' to disable console idle timeout in Menu
24.8 and stay in Menu 24.8
• Download ZyNOS via LAN
• Upload SMT configurations via LAN
c:\tftp -i [PrestigeIP] put [localfile] rom-0
• Download SMT configurations via LAN
c:\tftp -i [PrestigeIP] get ras [localfile]