3.4 Configuring Examples with AT Commands
This section shows you some examples of configuring the TA using AT commands.
!pP0=n Set incoming call screen mode for the analog port.
p: enter 1 or 2 to specify the analog port.
n=0: Accept all incoming calls (default).
n=1: Reject all incoming calls.
n=2: Only accept the calls from the phone number in the list (see !pId=<phone
number> [/<sub-address>]).
n=3: Only reject the calls from the phone number in the list (see !pId=<phone
number> [/<sub-address>]).
!pP1=n Set outgoing call screen mode for the analog port.
p: enter 1 or 2 to specify the analog port.
n=0: No restriction (default).
n=1: Prohibit all outgoing calls.
n=2: Only accept the calls with the prefix in the pre-defined list (see
!pOd=<prefix digits>).
n=3: Only reject the calls with the prefix in the pre-defined list (see
!pOd=<prefix digits>).
!pP2=n Select CLIP (Calling Line Identification Presentation) or CLIR (Calling Line
Identification Restriction) for the analog port.
p: enter 1 or 2 to specify the analog port.
n=0 indicates you select CLIR and the ISDN switch will not pass your phone
number to the destination site.
n=1 indicates you select CLIP and the ISDN switch will pass your phone number
to the destination site.
!pS=<phone
number> [/<sub-
address>]
Assign you phone number to the analog port.
p: enter 1 or 2 to specify the analog port.
<phone number>: Enter up to 32 characters, including digits from 0 to 9, *, #,
hyphen ( -), comma (,) and (‘,’). [‘,’] will be ignored.
<sub-address>: Enter up to 20 ASCII characters ranging from “0-9”,” a-z” and
“A-Z”.
$D99 Upgrade firmware.
$C0? Display the charge information of the last call.
Use $C0=0 to clear the information.
$C1? Display the accumulative charge information of the calls.
Use $C0=1 to clear the information.
$F99 Reset all parameters to the factory defaults.
$P5=<country
selection code>
Set three-digit country code for caller ID signaling (FSK or DTMF).
The default is 216.
Table 15 AT Command Sets for the Analog Port
COMMAND DESCRIPTION