NetAtlas Enterprise Ethernet Switch Manager User’s Guide Version 1.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Copyright Copyright © 2005 by ZyXEL Communications Corporation. The contents of this publication may not be reproduced in any part or as a whole, transcribed, stored in a retrieval system, translated into any language, or transmitted in any form or by any means, electronic, mechanical, magnetic, optical, chemical, photocopying, manual, or otherwise, without the prior written permission of ZyXEL Communications Corporation.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Federal Communications Commission (FCC) Interference Statement This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: • This device may not cause harmful interference. • This device must accept any interference received, including interference that may cause undesired operations.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Safety Warnings For your safety, be sure to read and follow all warning notices and instructions. • To reduce the risk of fire, use only No. 26 AWG (American Wire Gauge) or larger telecommunication line cord. • Do NOT open the device or unit. Opening or removing covers can expose you to dangerous high voltage points or other risks. ONLY qualified service personnel can service the device. Please contact your vendor for further information.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide ZyXEL Limited Warranty ZyXEL warrants to the original end user (purchaser) that this product is free from any defects in materials or workmanship for a period of up to two years from the date of purchase.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Customer Support Please have the following information ready when you contact customer support. • • • • Product model and serial number. Warranty Information. Date that you received your device. Brief description of the problem and the steps you took to solve it. TELEPHONEA WEB SITE SALES E-MAIL FAX FTP SITE support@zyxel.com.tw +886-3-578-3942 sales@zyxel.com.tw +886-3-578-2439 www.zyxel.com ZyXEL Communications Corp. www.europe.zyxel.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide TELEPHONEA WEB SITE SALES E-MAIL FAX FTP SITE support@zyxel.co.uk +44 (0) 8702 909090 www.zyxel.co.uk sales@zyxel.co.uk +44 (0) 8702 909091 0906 7370001(UK only) ftp.zyxel.co.uk METHOD SUPPORT E-MAIL REGULAR MAIL LOCATION UNITED KINGDOM ZyXEL Communications UK Ltd.,11 The Courtyard, Eastern Road, Bracknell, Berkshire, RG12 2XB, United Kingdom (UK) a. “+” is the (prefix) number you enter to make an international telephone call.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table of Contents Copyright .................................................................................................................. 2 Federal Communications Commission (FCC) Interference Statement ............... 3 Safety Warnings ....................................................................................................... 4 ZyXEL Limited Warranty....................................................................................
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 3.2 Device Icon Colors .............................................................................................37 3.3 System Message Panel Alarm Status ................................................................37 3.4 System Message Panel Port Status ...................................................................38 3.5 Menu Shortcut Buttons .......................................................................................38 3.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 6.3.1 IP Multicast Addresses .............................................................................62 6.3.2 Configuring an IGMP Filter Template ........................................................62 6.3.3 New IGMP Filter Template Screen ...........................................................63 6.4 Static Multicast Group Template .........................................................................64 6.4.1 Multicast MAC Address .....
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Chapter 11 Tools ........................................................................................................................ 94 11.1 Accessing the Switch .......................................................................................94 11.1.1 Telnet ......................................................................................................94 11.1.2 Web Access ............................................................
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 14.10 DSCP ...........................................................................................................126 Chapter 15 VLAN ..................................................................................................................... 128 15.1 Introduction to VLANs ....................................................................................128 15.2 Configuring 802.1Q VLAN ..................................................
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 18.3 MVR ...............................................................................................................158 18.3.1 Types of MVR Ports ..............................................................................159 18.3.2 MVR Modes ..........................................................................................159 18.3.3 Viewing MVR Settings ..........................................................................159 18.3.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide List of Figures Figure 1 SNMPc: Switch Device List Icon ........................................................................... 25 Figure 2 NetAtlas Main Screen ...................................................................................... 26 Figure 3 EMS: Main Screen ............................................................................................... 26 Figure 4 Switch Manager ...............................................
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 39 Provisioning: IGMP Filter: Remove From Devices: Select Device ..................... 73 Figure 40 Provisioning: IGMP Filter: Remove From Devices: Successful ......................... 73 Figure 41 Performance: Interface ....................................................................................... 74 Figure 42 Table Menu Bar Icons .........................................................................................
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 82 Switch Configuration: Filtering ........................................................................... 122 Figure 83 Switch Configuration: Filtering: Add .................................................................. 122 Figure 84 Switch Configuration: MAC Forwarding .............................................................. 124 Figure 85 Switch Configuration: MAC Forwarding: Add .................................................
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 125 EMS: Remove ................................................................................................... 167 Figure 126 Automatic Startup .............................................................................................. 168 Figure 127 SNMPc Main Windows ..................................................................................... 169 Figure 128 SNMPc Main Button Bar Icons .........................................
NetAtlas Enterprise Ethernet Switch Manager User’s Guide List of Tables Table 1 System Requirements ........................................................................................... 24 Table 2 Device Firmware Versions Supported ................................................................... 25 Table 3 Switch Manager Menus Overview ......................................................................... 28 Table 4 Switch Manager: Admin: Access Log .............................................
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 39 Configuration Window ......................................................................................... 99 Table 40 Copy Port Setup .................................................................................................. 101 Table 41 SNMP Commands ............................................................................................... 105 Table 42 System Configuration: SNMP Conf. .......................................
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 82 General Installation Problems ............................................................................. 166 Table 83 Problems Accessing the EMS ............................................................................. 166 Table 84 Problems Accessing the EMS ............................................................................. 167 Table 85 SNMPc Main Window .......................................................................
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 21 List of Tables
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Preface Congratulations on your purchase of the NetAtlas Enterprise Ethernet Switch Manager for the ES-3124 series, ES-2024A. and GS-2024. The Ethernet Switch Manager is an Element Management System (EMS) that retrieves management information from switches using SNMP. Note: Register your product online to receive e-mail notices of firmware upgrades and information at www.zyxel.com for global products, or at www.us.zyxel.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide User Guide Feedback Help us help you. E-mail all User Guide-related comments, questions or suggestions for improvement to techwriters@zyxel.com.tw or send regular mail to The Technical Writing Team, ZyXEL Communications Corp., 6 Innovation Road II, Science-Based Industrial Park, Hsinchu, 300, Taiwan. Thank you.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 1 Introduction This chapter introduces and shows you how to access the EMS (Element Management System). 1.1 EMS Overview The Element Management System (EMS) retrieves management information from switches using the SNMP protocol. An EMS is composed of Network Elements (NE) that represent resources in a Network Management System (NMS).
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 1 System Requirements (continued) HARDWARE SOFTWARE Screen Resolution: 1024x768 pixels Ethernet Adaptor: 10/100 Mbps 1.2.1 Device Firmware Versions Supported1 The EMS supports the devices and device firmware versions as listed in the following tale.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 2 NetAtlas Main Screen Figure 3 EMS: Main Screen Chapter 1 Introduction 26
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 27 Chapter 1 Introduction
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 2 Switch Manager This chapter describes the Switch Manager screens. 2.1 Switch Manager Overview Use the Switch Manager screens to view EMS and device logs and database management. In SNMPc, double-click on a device icon to display the main Switch Manager screen as shown. Figure 4 Switch Manager The following table describes the options in the switch manager screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 3 Switch Manager Menus Overview (continued) LABEL Help MENU SUB-MENU DESCRIPTION Scheduled Backup Configuration (EMS DB) Use this screen to specify when to store logs in the database. On-line Help Select On-line Help to display an EMS help file. 2.2 Access Log To view access logs, click Admin and then Access Log in the Switch Manager screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 4 Switch Manager: Admin: Access Log (continued) LABEL DESCRIPTION Sorted by Select By Device Name to sort the logs displayed in alphabetical order according to the names of the switch(es). Select Log Time to sort the logs displayed according to the times received on the switch(es). Date Select a start date and end date from the list boxes to display logs for that period. Apply Click Apply to display logs with the criteria set above.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 6 Switch Manager: Admin: Database Management: Backup/Restore The following table describes the fields in this screen. Table 5 Switch Manager: Admin: Database Management: Backup/Restore LABEL DESCRIPTION Directory Specify the location you wish the EMS to restore from or back up to on your computer or click Browse to locate it. Backup Select Backup to transfer the database file from the EMS to the computer.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 6 Switch Manager: Admin: Database Management: Log Storage LABEL DESCRIPTION Storage Configuration Configure the following fields to retain daily records. Select the first radio button and a number (in thousands) from the drop-down list box to retain that number of records. All records prior to these records are cleared every 24 hours. Or Select the second radio button and a number (from 7 to 365) in the field provided.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 7 Switch Manager: Admin: Database Management: Scheduled Backup LABEL DESCRIPTION Backup Schedule Frequency Scheduled backups can be performed Daily, Weekly or Monthly. Select a radio button to schedule database backups starting from the date and time specified below. The default setting is No Backup. Starting date Specify the starting date to begin database backup for the selected device(s). Select a date from the drop-down list box.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 9 EMS: Main Screen Chapter 2 Switch Manager 34
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 35 Chapter 2 Switch Manager
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 3 EMS Main Window This chapter describes the EMS main window. 3.1 Introducing the EMS Main Window After you have accessed the EMS, double-click the switch device icon in the Device List Panel to display the EMS main screen. The EMS retrieves device information from the switch (using SNMP protocol). The EMS main screen varies depending on the selected switch model.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 8 EMS Main Screen Overview ELEMENT FUNCTION 1 Menu Shortcut Bar Use these buttons to execute common commands quickly. Hold the cursor over an icon to see a tool tip. 2 Device List Panel View devices in a tree structure. The colors of the device icons indicate the time status of the represented devices. 3 Alarm Severity Icons These icons indicate the presence of any alarm/event logs.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 10 System Message Panel Alarm Status (continued) PANEL ALARMS ALARM OFF ALARM ON TEMP When this icon is gray out, temperatures at all sensor points in the switch are within the threshold temperature range. The temperature at a sensor point in the switch has risen above or below the threshold temperature range. VOL When this icon is gray out, the power supply at all sensor points in the switch is within the tolerance range.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 3.6 EMS Main Menu Summary This is a summary of the EMS menus in the main screen. Screens, screen labels and fields vary depending on your switch model.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 12 EMS Navigation Panel Sub-link Descriptions (continued) DESCRIPTION LABEL 802.1d This link takes you to a screen where you can view the MAC addresses (and types) of devices attached to what ports and VLAN IDs or view the MAC addresses – IP address resolution table. Multicast Status This link takes you to a screen where you can view the multicast traffic status of a device.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 3.7 Common EMS Command Buttons The following table shows common command buttons found on most EMS screens. Table 13 Common EMS Command Buttons LABEL DESCRIPTION Apply Click Apply to save the changes back to the switch. OK Click OK to save your changes and close the screen. Cancel Click Cancel to discard all changes and close the screen. Close Click Close to close the screen. 3.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 13 Configuration: System Configuration: System Info The following table describes the labels in this screen. Table 14 Configuration: Switch System Configuration LABEL DESCRIPTION Name Enter a descriptive name for identification purposes. If you want to change the name, enter up to 32 printable characters; spaces are not allowed. Contact Enter the name (up to 32 characters) of the person in charge of the selected switch.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Note: Do NOT turn off the switch during the updating process, as it may corrupt the firmware and make your switch unusable. 1 To save the current switch configuration, right-click on the switch icon in the Device List Panel. 2 Click Configuration Save. 3 Choose a switch from the list located in the screen. Figure 14 Configuration Save 4 Click Apply to save the current configuration.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 4 Map This chapter describes the Map screens you use to add, edit or delete device mappings in the EMS. 4.1 Submap and Device Mapping The EMS mapping displays logical hierarchy for the switch in the EMS. When you first start the EMS, the default Root Map and an icon for your switch device are created in the Device List Panel automatically. Both devices and submaps (or folders) can be added below the rootmap.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 17 Map: Add Submap/Device The following table describes the labels in this screen. Table 15 Map: Add Submap/Device LABEL DESCRIPTION Properties Select the Submap or Device radio button to add a new submap or device icon to the Device List Panel. If you select Submap, only the Name and Description fields display; all other fields appear as read-only.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 18 Map: Edit Node Refer to Table 15 on page 45 for the field descriptions. 4.1.3 Find an Object To find or locate a device (or node), click Map and then Find Object. Figure 19 Map: Find Object Enter a descriptive text (for example, the node name) in the Find field and click OK to start the search. 4.1.4 Delete a Submap To delete a submap, select the submap icon in the Device List Panel and click Map and then Delete.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 4.1.5 Delete a Device To remove a device from the Device List Panel, select the device icon and click Map and then Delete. 4.2 Exit Click Map and then Exit to close the EMS screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 5 View This chapter describes the hardware status, STP status, VLAN status, port status and 802.1d status View screens. 5.1 Hardware Status1 View fan speeds, voltage levels and temperatures of a selected switch in the Hardware Monitor screen. Click View and then Hardware Status and select a switch from the device list located on the left-hand side of the screen. The device hardware status displays.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 16 Status: Hardware Status LABEL DESCRIPTION Fan RPM (RPM) A properly functioning fan is an essential component (along with a sufficiently ventilated, cool operating environment) in order for the device to stay within the temperature threshold. Each fan has a sensor that is capable of detecting and reporting if the fan speed falls below the threshold shown. Index This field displays the fan number.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 5.2 Spanning Tree Protocol (STP) STP detects and breaks network loops and provides backup links between switches, bridges or routers. It allows a switch to interact with other STP-compliant switches in your network to ensure that only one route exists between any two stations on the network. 5.2.1 STP Terminology The root bridge is the base of the spanning tree; it is the bridge with the lowest identifier value (MAC address).
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Once a stable network topology has been established, all bridges listen for Hello BPDUs (Bridge Protocol Data Units) transmitted from the root bridge. If a bridge does not get a Hello BPDU after a predefined interval (Max Age), the bridge assumes that the link to the root bridge is down. This bridge then initiates negotiations with other bridges to reconfigure the network to re-establish a valid network topology. 5.2.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 19 View: STP Status LABEL DESCRIPTION STP This field displays Running if STP is activated; otherwise, it displays Down. Bridge Root refers to the base of the spanning tree (the root bridge). Bridge ID This is the unique identifier for this bridge, consisting of bridge priority plus MAC address. Hello Time (second) This is the time interval (in seconds) at which the root device transmits a configuration message.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 23 View: VLAN Status The following table describes the labels in this screen. Table 20 View: VLAN Status LABEL DESCRIPTION VLAN ID This field displays the identification number of the VLAN. Name This field displays a unique number for identification purposes. Elapsed Time This field displays the time since the VLAN was created.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 24 View: Port Status The following table describes the labels in this screen. Table 21 View: Port Status LABEL DESCRIPTION Port This identifies the Ethernet port. Link Speed This field displays the speed (either 10M for 10Mbps, 100M for 100Mbps or 1000M for 1000Mbps). State This field displays the STP state of the port. See the Spanning Tree Protocol chapter for details on STP port states.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 5.5 802.1D Use the following screens to view a table of MAC address entries or to view a table of IP address mappings. 5.5.1 802.1D: MAC Table The MAC table shows how frames are forwarded or filtered across the switch’s ports. It shows what device MAC address, belonging to what VLAN group (if any) is forwarded to which port(s) and whether the MAC address is dynamic (learned by the switch) or static (manually entered in Static MAC Forwarding).
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 1 Click View and then 802.1d. 2 To view the MAC table of a switch choose a switch from the list located on the left-hand side of the screen and click the MAC Table tab. Figure 26 View: 802.1d: MAC Table The following table describes the labels in this screen. Table 22 View: 802.1d: MAC Table LABEL DESCRIPTION Sort by Click one of the following buttons to display and arrange the data according to that button type.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 5.5.3 802.1D: ARP Table Address Resolution Protocol (ARP) is a protocol for mapping an Internet Protocol address (IP address) to a physical machine address, also known as a Media Access Control or MAC address, on the local area network. An IP (version 4) address is 32 bits long. In an Ethernet LAN, MAC addresses are 48 bits long. The ARP Table maintains an association between each MAC address and its corresponding IP address. 5.5.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 27 View: 802.1d: ARP Table The following table describes the labels in this screen. Table 23 View: 802.1d: ARP Table LABEL DESCRIPTION Index This is the ARP table entry number. IP Address This is the learned IP address of a device connected to a switch port with corresponding MAC address below. MAC Address This is the MAC address of the device with corresponding IP address above.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 28 View: Multicast Status The following table describes the labels in this screen. Table 24 View: Multicast Status 59 LABEL DESCRIPTION Index This field displays the index number. VID This field displays the multicast VLAN ID. Port This field displays the port number(s) that belongs to the multicast group. Multicast Group This field displays the multicast group address.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 6 Template This chapter describes how to configure VLAN, IGMP filtering and multicast templates. 6.1 Template Overview A template is a pre-configured set of configuration settings. Templates allow you to configure device VLANs efficiently. The template can then be uploaded to one or more devices thus removing the need to configure the VLAN settings for each device.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide The following table describes the labels in this screen. Table 25 Template: VLAN LABEL DESCRIPTION Device Type Select a device from the drop-down list box to view the device’s VLAN configuration. VLAN Identity VLAN ID Enter a unique number to identify the VLAN. VLAN Name Enter a descriptive name for identification purposes. Egress Ports A port that is in the egress list in a VLAN.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide IGMP filter templates allow you to control access to IGMP multicast groups. This allows you to have a service available to a specific IGMP multicast group. You can configure an IGMP filter template for an IGMP multicast group that has access to a service (like a SIP server for example). 6.3.1 IP Multicast Addresses In IPv4, a multicast address allows a device to send packets to a specific group of hosts (multicast group) in a different subnetwork.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 26 Template: IGMP Filter (continued) LABEL DESCRIPTION Modify Click Modify to edit a selected IGMP filter profile. IGMP Filter Parameters This table displays the settings of the selected IGMP filter above. OK Index This is the number of the IGMP filter profile. Start IP This field displays the starting multicast IP address for a range of multicast IP addresses to which you want this IGMP filter profile to allow access.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 27 Template: New IGMP Filter LABEL DESCRIPTION No. This field displays the index number. IGMP Filter Name Type a name (up to 31 printable characters) to identify the IGMP filter profile. New/Add Click New/Add to create a new IGMP filter template. Delete Click Delete to remove the selected IGMP filter template. Modify Click Modify to change the settings of the selected IGMP filter template.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 6.4.1 Multicast MAC Address All Ethernet devices must have a unique MAC address to communicate with one another. Device such as routers and switches on the LAN keeps a table of MAC-IP address mappings. When a packet is received, the destination IP address is looked up in the address mapping table and the packet is forwarded to the intended Ethernet device.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 33 Template: Multicast The following table describes the labels in this screen. Table 28 Template: Multicast LABEL DESCRIPTION Device Type Select a device from the drop-down list box to view the device’s VLAN configuration. Template No. This field displays the index number. Multicast Name This field displays the descriptive name for the multicast template. New Click New to create a new multicast template.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 28 Template: Multicast (continued) LABEL DESCRIPTION IGMP Filtering This field displays the name of the IGMP filtering profile to use for this port. Close Click Close to close this screen. 6.4.3 New Multicast Template Screen To create a new multicast template, click New in the Multicast Template screen. A screen displays as shown. Figure 34 Template: New Multicast The following table describes the labels in this screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 29 Template: New Multicast (continued) LABEL DESCRIPTION OK Click OK to save the settings and close this screen. Cancel Click Cancel to discard all changes and close this screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 69 Chapter 6 Template
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 7 Provisioning This chapter shows you how to use the Provisioning screens to apply templates. 7.1 Provisioning Overview After you have created an IGMP filter profile (or template) in the Template screens, you can use the Provisioning screens to apply or delete IGMP filter profiles to or from a device. Note: You must first create IGMP filtering templates before you can apply them using the Provisioning screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 35 Provisioning: IGMP Filter 4 Click Apply To Devices to apply the selected IGMP filer profile(s). 5 A screen displays as shown. Select the device(s) to which you want to apply the IGMP filter(s). To select more than one device, press [SHIFT] or [CTRL] and select at the same time. Figure 36 Provisioning: IGMP Filter: Apply to Devices 6 Click Apply to copy the IGMP filter profile settings to the selected device(s).
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 37 Provisioning: IGMP Filter: Apply to Devices: Successful 7.3 Removing an IGMP Filter Profile Follow the steps below to remove an IGMP filter from a device. 1 Click Provisioning and IGMP Filter Provision to display the screen as shown. 2 Select Remove IGMP Filters under Action. 3 Select a profile you want to remove and click Add. You can view the profile settings by clicking View IGMP Filter.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 39 Provisioning: IGMP Filter: Remove From Devices: Select Device 6 Click OK to remove the IGMP filter profile settings from the selected device(s). 7 A Result screen displays showing the profile removal status. Click Close to close this screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 8 Performance This chapter describes the interface performance screen, graph setup and table setup. View Ethernet history statistics for your switch network. 8.1 Interface Performance This section shows you how to configure what you want to display in a performance table or graph. Click Performance and then Interface in the EMS main menu. Figure 41 Performance: Interface The following table describes the labels in this screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 30 Performance: Interface (continued) LABEL DESCRIPTION Non-unicast Pkts Select this option to show the total number of good non-unicast packets received or transmitted that were dropped. Discard Pkts Select this option to show the total number of packets received or transmitted that were dropped. Error Pkts Select this option to show the total number of error packets received or transmitted.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 8.2.1 Editing a Table Entry Note: You can edit a table entry in all screens that display information in tabular format. In any tabulated screen display, click the Edit icon in the menu bar icon to display the Edit Table Entry screen and edit any field in a table. There is a set of variable names, value and set button controls that operate on the fields of the selected table. There is also a set of function control buttons on the right.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 31 Edit Table Entry (continued) COMMAND DESCRIPTION Previous/Next Page Buttons Each page shows up to ten variables. The page number and total number of pages are displayed in the top right corner. Use the >> button to move to the next page and click the << button to move to the previous page. Expand Click the Expand button to expand the view of the active variable value edit box. First click on the edit box, then select the Expand button.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 44 Expand Field The Expand screen shows the variable value in a larger edit box, so you can more easily enter a long value. It also shows the variable type and a description from the MIB source file. Possible variable types are shown in the following table. Table 32 Variable Types TYPE DESCRIPTION Number This can be an INTEGER, COUNTER, GAUGE or Time Ticks. Data is normally represented as a decimal number.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 45 Graph Menu Bar Restart Save to Bar Graph File Chart Pause Graph Poll Interval Line Pie Distribution Graph Chart Paging Scroll Controls Controls Vertical Scale 8.3.1 Graph Styles Use one of the style buttons to change the graph style to one of the following: Table 33 Edit Table Entry STYLE DESCRIPTION Line Each variable is displayed as a line, with time as the horizontal axis.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 46 Cell Properties Select 4 A display properties dialog box opens. Select the Display check box. Figure 47 Chart Color Codes and Line Styles You may also edit the color code and line style for a variable in the dialog box as described in the following table. Table 34 Edit Style Dialog Box FIELD DESCRIPTION Display Check Display to view information about this variable in chart format. Color Choose a color from this drop down list.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 48 Graph Variables The following table describes the labels in this screen. Table 35 Graph Variables LABEL DESCRIPTION Style This is the line style discussed above. Variable This is the variable being represented by the line style discussed above. Scale This is the scaling multiplier. Cur This is the current value of the variable. Min This is the minimum value of the variable. Max This is the maximum value of the variable.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 9 Fault This chapter describes the event logs and how to perform loopback tests using the Fault screens. 9.1 Event Log To display system event logs click Fault and then Event Log to view the following screen. Figure 49 Fault: Event Log The following table describes the labels in this screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 36 Fault: Event Log (continued) LABEL DESCRIPTION Alarm Type Select the type of logs from the drop-down list box. Choices are All, Communication, QualityOfService, ProcessingError, Equipment and Environmental. Select All for system event logs generated by all alarm types. Select Communication for transmission and signal logs. Select QualityOfService for performance logs. Select Processing Error for software and configuration problem logs.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 3 Choose a port from the list located on the right-hand side of the screen. 4 In the Timeout field, accept the default or specify a connection timeout period (in seconds). 5 Click Apply to start the loopback test. Figure 50 Fault: Loopback Test 6 A screen displays showing the test result. Click OK to close the screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 85 Chapter 9 Fault
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 10 Maintenance This chapter tells you how to backup and restore your configuration file as well as upload new firmware and configuration files. 10.1 Firmware Upgrade You must be logged in with system administrator rights to use this function. Note: Do NOT turn off the switch during the updating process, as it may corrupt the firmware and make the selected switch unusable. 10.1.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 52 Maintenance: Firmware Upgrade 5 After the file transfer is complete, a screen displays showing the result. Click Done to close the screen. When the firmware upgrade process is complete, the switch(es) automatically restarts (the SYS LED blinks). Figure 53 Maintenance: Firmware Upgrade: Result 6 Wait until the switch(es) has finished rebooting before accessing it again.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 54 Maintenance: Device Reset 3 A screen displays. Click Done. The switch will restart. This takes up to two minutes. This does NOT affect the switch’s configuration. Figure 55 Maintenance: Device Reset: Result 10.3 Network Element Configuration Backup and Restore A Network Element (NE) is a network device that provides support or services to the user. Follow the steps below to backup or restore a switch configuration file to your computer.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 6 Click Apply. 7 If you chose Restore, the switch automatically restarts when the configuration file upload is complete. 8 Click Close to close this screen. Figure 56 Maintenance: Configuration Backup/Restore The following table describes the labels in this screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide This takes up to two minutes. If you want to access the switch web configurator again, you may need to change the IP address of your computer to be in the same subnet as that of the default switch IP address. 4 Click Close to close this screen. Figure 57 Maintenance: Load Factory Defaults 10.5 Scheduled Network Element Configuration Backup Perform configuration backups according to a schedule.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 38 Maintenance: Scheduled NE Config Backup LABEL DESCRIPTION Backup Schedule Frequency Scheduled backups can be performed on a Daily, Weekly or Monthly basis. Select a radio button to schedule configuration backups starting at the date and time specified below. The default setting is No Backup. Starting date Specify the starting date to begin a configuration file backup for the selected device(s). Select a date from the drop-down list box.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 59 Maintenance: Scheduled NE Config Backup Add 10.5.2 Scheduled Network Element Configuration Backup Remove To remove a device from the Scheduled NE Configuration Backup screen, click the Remove button in the Scheduled NE Config Backup screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 93 Chapter 10 Maintenance
NetAtlas Enterprise Ethernet Switch Manager User’s Guide C H A P T E R 11 Tools This chapter shows you how to access a switch via Telnet or web configurator directly through the EMS. You may need to do this to test the switch network connection for example. 11.1 Accessing the Switch Access the switch remotely via Telnet or web browser. Note: When you access a switch via Telnet or the web configurator, you CANNOT make any changes to that switch using the EMS. 11.1.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 11.1.2 Web Access Configure the switch using the web configurator as shown. 1 Select a switch from the list of devices shown in the Device List Panel. 2 Click Tool and then Web Access to open the switch web configurator password screen. From here you can log in directly to the switch. 3 Type the switch User name and Password to access the web configurator.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 62 Ping Chapter 11 Tools 96
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 97 Chapter 11 Tools
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 12 Device Menu Overview This chapter introduces the device configuration menus. 12.1 Device Menu Summary To select a device configuration menu, right-click on a device in the Device List Panel. Figure 63 Device Panel List Menus 12.2 Property Configuration See Section 4.1.2 on page 45 for information on the Edit Device screen. 12.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 64 Configuration Window 3 1 4 2 5 The following table describes the elements in this screen. Table 39 Configuration Window LABEL DESCRIPTION 1 Device Panel This panel displays all active devices (of the same type) currently managed by the EMS. 2 Port List Panel This field displays a list of switch ports. This list displays in the Ethernet Port Configuration screens only.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 65 Configuration Window: Port List: Multiple Port Select Click Apply when you are satisfied with the configuration changes. A screen displays showing the configuration result. Figure 66 Applied Results 4 Click Done to close the screen. 12.3.2 The Copy to.. Button The Copy to.. button allows you to copy the configuration from the switch you are currently configuring to one or more switches.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 67 Copy Port Setup: Example Device List Panel Port List Panel Copy Port List Panel The following table describes this screen. Table 40 Copy Port Setup LABEL DESCRIPTION Device List Select a device to which you want to copy from the switch you are currently configuring. Port List Panel Select one port or multiple ports (by pressing the [CTRL] key and clicking at the same time) from the Port List Panel.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 68 Copy Successful 7 Click Done to close the screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 103 Chapter 12 Device Menu Overview
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 13 System Configuration This chapter shows you how to view general system information, configure SNMP, remote management and time setup. 13.1 System Info See Section 3.9 on page 41 for information about the switch. 13.2 SNMP Simple Network Management Protocol is a protocol used for exchanging management information between network switches. SNMP is a member of TCP/IP protocol suite.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide The managed devices contain object variables/managed objects that define each piece of information to be collected about a switch. Examples of variables include such as number of packets received, node port status etc. A Management Information Base (MIB) is a collection of managed objects. SNMP allows a manager and agents to communicate for the purpose of accessing these objects.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 70 System Configuration: SNMP Conf. The following table describes the labels in this screen. Table 42 System Configuration: SNMP Conf. LABEL DESCRIPTION Get Community Enter the get community, which is the password for the incoming Get- and GetNext- requests from the management station. Set Community Enter the set community, which is the password for incoming Set- requests from the management station.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 71 System Configuration: Remote Management The following table describes the labels in this screen. Table 43 System Configuration: Remote Management LABEL DESCRIPTION Services This panel displays the services that you may use to remotely manage the switch. Select the check box(es) to allow remote management using the service(s). Port Enter the number of the server port to use with the corresponding service.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 13.4 Time Setup The switch keeps track of the time and date. There is also a software mechanism to set the time manually or get the current time and date from an external server when you log in to the switch. Use the Time Setup screen to update the time and date settings in the EMS and then save the settings to the switch. The real time is then displayed in the system messages. Follow the steps below to configure your system time.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 44 System Configuration: Time Setup (continued) 109 LABEL DESCRIPTION Time Zone Select the time difference between your time zone and Universal Time Coordinate (UTC) formerly known as Greenwich Mean Time (GMT). Apply Click Apply to save the changes.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 14 Switch Configuration This chapter shows how to configure priority queuing, STP, link aggregation, DHCP relay, GARP timer and RADIUS. 14.1 Switch Setup Use the switch setup screen to set a VLAN type, a queuing method and enable or disable features in the Active Control panel. 1 In the Device Panel list, select a device and then right-click. 2 Click Configuration, Switch Configuration. The Switch Setup screen displays.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 74 Switch Configuration: Switch Setup (GS-2024) Figure 75 Switch Configuration: Switch Setup (ES-3124/ES-3124PWR) 111 Chapter 14 Switch Configuration
NetAtlas Enterprise Ethernet Switch Manager User’s Guide The following table describes the related labels in the screen. Table 45 Switch Configuration: Switch Setup LABEL DESCRIPTION VLAN Type Choose 802.1Q or Port Based from the drop-down list box. The VLAN Setup screen changes depending on whether you choose 802.1Q or Port Based VLAN type in this screen. See Section 16.3 on page 137 and the VLAN chapter for more information on VLANs.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 45 Switch Configuration: Switch Setup (continued) LABEL DESCRIPTION VLAN Stacking Select the check box to enable VLAN stacking. In the SP TPID drop-down list box, select a standard Ethernet type code to identify the frame and indicate whether the frame carries IEEE 802.1Q tag information. Or select Others and then enter a four-digit hexadecimal number from 0x0000 to 0xFFFF. 0x denotes a hexadecimal number.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide The following table describes the labels in this screen. Table 46 Switch Configuration: Priority Queue LABELS DESCRIPTION Priority Queue Assignment IEEE 802.1p defines up to 8 separate traffic types by inserting a tag into a MAC-layer frame that contains bits to define class of service. Frames without an explicit priority tag are given the default priority of the ingress port.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 77 Switch Configuration: STP Conf. The following table describes the labels in this screen. Table 47 Switch Configuration: STP Conf. LABEL DESCRIPTION Priority Priority is used in determining the root device, root port and designated port. The device with the highest priority (lowest numeric value) becomes the RSTP root device. If all devices have the same priority, the device with the lowest MAC address will then become the root device.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide The first port must be physically connected when forming a trunk group. 14.4.1 Dynamic Link Aggregation This feature is not available on all models. The switch adheres to the IEEE 802.3ad standard for static and dynamic (LACP) port trunking. The switch supports the link aggregation IEEE 802.3ad standard. This standard describes the Link Aggregate Control Protocol (LACP), which is a protocol that dynamically creates and manages trunk groups.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 14.4.3 Configuring Link Aggregation Activate link aggregation in the Switch Setup screen. 1 Right-click on a device in the Device Panel list. 2 Click Configuration, Switch Configuration and then the Link Aggregation tab to display the following screen. Note: The number of link aggregation groups varies depending on your switch models. Figure 78 Switch Configuration: Link Aggregation The following table describes the labels in this screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide If there is an Ethernet device that performs the DHCP server function for your network, then you can configure the switch as a DHCP relay agent. When the switch receives a request from a computer on your network, it contacts the Ethernet device (the DHCP server) for the necessary IP information, and then relays the assigned information back to the computer. 14.4.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide The following table describes the labels in this screen. Table 51 Switch Configuration: DHCP Relay LABEL DESCRIPTION DHCP Relay Service Relay Option82 From the drop-down list box, select Enable to have the switch add information (slot number, port number and VLAN ID) to client TCP/IP configuration requests that it relays to a DHCP server. Otherwise, select Disable.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 80 Switch Configuration: GARP Timer The following table describes the labels in this screen. Table 52 Switch Configuration: GARP Timer LABEL DESCRIPTION Join Timer Join Timer sets the duration of the join period timer for GVRP in milliseconds. Each port has a join period timer. The allowed join time range is between 10 and 6553 centiseconds; the default is 20 centiseconds. See the chapter on VLAN setup for more background information.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 81 Switch Configuration: RADIUS The following table describes the labels in this screen. Table 53 Switch Configuration: RADIUS LABEL DESCRIPTION Authentication Server IP Address Enter the IP address of the external RADIUS server in dotted decimal notation. UDP Port The default port of the RADIUS server for authentication is 1812. You need not change this value unless your network administrator instructs you to do so.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 82 Switch Configuration: Filtering The following table describes the labels in this screen. Table 54 Switch Configuration: Filtering LABEL DESCRIPTION Index This field displays the index number. Active This field displays whether the filter is enabled (Yes) or not (No). Name This field displays the descriptive name for this filter. MAC Address This field displays the MAC address of a device whose traffic is forwarded or blocked.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide The following table describes the related labels in this screen. Table 55 Switch Configuration: Filtering: Add LABEL DESCRIPTION Active Make sure to select this check box to activate your rule. You may temporarily deactivate a rule without deleting it by deselecting this check box. Name Type a descriptive name (up to 32 printable ASCII characters) for this rule. This is for identification purpose only.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 84 Switch Configuration: MAC Forwarding The following table describes the labels in this screen. Table 56 Switch Configuration: MAC Forwarding LABEL DESCRIPTION Index Click an index number to modify a static MAC address rule for a port. Active This field displays whether this static MAC address forwarding rule is active (Yes) or not (No). You may temporarily deactivate a rule without deleting it.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide The following table describes the labels in this screen. Table 57 Switch Configuration: MAC Forwarding: Add LABEL DESCRIPTION Active Select this check box to activate your rule. You may temporarily deactivate a rule without deleting it by clearing this check box. MAC Enter the MAC address in valid MAC address format, that is, six hexadecimal character pairs. Static MAC addresses do not age out. VID Enter the VLAN group identification number.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 87 Switch Configuration: Mirroring (GS-2024) Figure 88 Switch Configuration: Mirroring (ES-3124/ES-3124PWR) The following table describes the labels in this screen. Table 58 Switch Configuration: Mirroring LABEL DESCRIPTION Monitor Port The monitor port is the port you copy the traffic to in order to examine it in more detail without interfering with the traffic flow on the original port(s). Select a port from the dropdown list box.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide DiffServ defines a new DS (Differentiated Services) field to replace the Type of Service (ToS) field in the IP header. The DS field contains a 2-bit unused field and a 6-bit DSCP field which can define up to 64 service levels. The following figure illustrates the DS field. DSCP is backward compatible with the three precedence bits in the ToS octet so that nonDiffServ compliant, ToS-enabled network device will not conflict with the DSCP mapping.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 15 VLAN This chapter describes how to view VLAN status, add and edit VLANs and how to use the VLAN template. The type of screen you see here depends on the VLAN Type you selected in the Switch Setup screen. 15.1 Introduction to VLANs A VLAN (Virtual Local Area Network) allows a physical network to be partitioned into multiple logical networks. Devices on a logical network belong to one group. A device can belong to more than one group.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 91 Selecting a VLAN Type 4 Click Configuration and then VLAN Configuration to display the screen as shown next. Figure 92 VLAN Configuration: 802.1Q The following table describes the labels in this screen. Table 60 VLAN Configuration: 802.1Q 129 LABEL DESCRIPTION VLAN ID This field displays the ID of the VLAN. Name This field displays the name of the VLAN.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 60 VLAN Configuration: 802.1Q (continued) LABEL DESCRIPTION New Click New to create a new VLAN. You must enter a VLAN ID and a VLAN Name to create a new VLAN. The new VLAN and name is displayed in the left-hand column in this screen. Delete Click on a VLAN in the left-hand column of this screen and then click the Delete button to remove it from the VLAN template. Modify Click on a VLAN in the left-hand column of this screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide The following table describes the labels in this screen. Table 61 VLAN Configuration: 802.1Q: Modify LABEL DESCRIPTION VLAN Identity Active Select Active to enable this VLAN. VLAN ID This field displays a unique number to identify the VLAN. VLAN Name Enter a descriptive name for identification purposes. Static VLAN Click on a port in a list to add the selected port to the port list.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 15.3 Introduction to Port-based VLANs Port-based VLANs are VLANs where the packet forwarding decision is based on the destination MAC address and its associated port. Port-based VLANs require allowed outgoing ports to be defined for each port.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide The following table describes the labels in this screen. Table 63 VLAN Configuration: Port Based LABEL DESCRIPTION Setting Wizard Choose from All connected or Port isolation. All connected means all ports can communicate with each other, that is, there are no virtual LANs. All incoming and outgoing ports are selected. This option is the most flexible but also the least secure.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 16 Ethernet Port Configuration This chapter shows how to configure the Ethernet port settings. 16.1 Overview Use the Ethernet Port Configuration screens to set port-related settings (such as port VLAN, STP and security, etc.). Once you configure a feature on a port, you must enable that feature on the switch in the Switch Setup screen. 16.2 Port Setup Use the Port Setup screen to activate and configure switch port parameters.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 96 Ethernet Port Configuration: Port Setup (GS-2024) Figure 97 Ethernet Port Configuration: Port Setup (ES-3124/ES-3124PWR) The following table describes the fields in this screen. Table 64 Ethernet Port Configuration: Port Setup 135 LABEL DESCRIPTION Active Select this check box to enable a port. The factory default for all ports is enabled. A port must be enabled for data transmission to occur.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 64 Ethernet Port Configuration: Port Setup (continued) LABEL DESCRIPTION Speed/Duplex Select the speed and the duplex mode of the Ethernet connection on this port. Choices are Auto, 10M/Half Duplex, 10M/Full Duplex, 100M/Half Duplex, 100M/Full Duplex and 1000M/Full Duplex (for Gigabit/mini-GBIC ports only).
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 16.3 Port VLAN Use the following screen to activate a port VLAN, GVRP and VLAN trunking. 16.3.1 Configuring Port VLAN Follow the steps below to configure the Port VLAN screen. 1 In the Device Panel list, select a device and then right-click. 2 Click Configuration, Ethernet Port Configuration and then the Port VLAN tab. 3 Select the ports from the Port List Panel to which you want to apply this configuration.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 65 Ethernet Port Configuration: Port VLAN (continued) LABEL DESCRIPTION VLAN Trunking Enable VLAN trunking on ports connected to other switches or routers (but not ports directly connected to end users) to allow frames belonging to unknown VLAN groups to pass through the switch. Apply Click Apply to save the changes. 16.4 Port Link Aggregation Use the Port Link Aggregation screen to configure a port trunk group and set LACP timeout.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 1 In the Device Panel list, right-click on a device. 2 Click Configuration, Ethernet Port Configuration and then the Port STP tab. 3 Select the ports from the Port List Panel that you want to apply this configuration. Figure 100 Ethernet Port Configuration: Port STP The following table describes the fields in this screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 101 Ethernet Port Configuration: Bandwidth Ctrl. Figure 102 Ethernet Port Configuration: Bandwidth Ctrl. (GS-2024) The following table describes the labels in this screen. Table 68 Ethernet Port Configuration: Bandwidth Ctrl. LABEL DESCRIPTION Active Select this check box to enable bandwidth control on the selected port(s). You may temporarily deactivate a rule without deleting it by clearing this check box.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 16.7 Broadcast Storm Control Broadcast storm control limits the number of broadcast, multicast and destination lookup failure (DLF) packets the switch receives per second on the ports. When the maximum number of allowable broadcast, multicast and/or DLF packets is reached per second, the subsequent packets are discarded. Enable this feature to reduce broadcast, multicast and/or DLF packets in your network.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide The following table describes the labels in this screen. Table 69 Ethernet Port Configuration: Broadcast Storm Ctrl. LABEL DESCRIPTION Active Select Active to enable broadcast storm control. Note: For GS-2024, configure rate limiting settings in the Switch Configuration: Switch Setup screen. Refer to Section 14.1 on page 110. Rate Specify the traffic a port receives in kilobits per second (Kbps).
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 106 Ethernet Port Configuration: DiffServ 16.9 Port 802.1x Use the Port 802.1x screen to configure reauthentication for selected ports. 1 In the Device Panel list, select a device and then right-click. 2 Click Configuration, Ethernet Port Configuration and then the Port 802.1x tab. 3 Select the ports from the Port List Panel that you want to apply this configuration. Figure 107 Ethernet Port Configuration: Port 802.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 16.10 Port Security Port security allows only packets with dynamically learned MAC addresses and/or configured static MAC addresses to pass through a port on the switch. The switch can learn up to 16K MAC addresses in total with no limit on individual ports other than the sum cannot exceed 16K. For maximum port security, enable this feature, disable MAC address learning and configure static MAC address(es) for a port.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide The following table describes the fields in this screen. Table 71 Ethernet Port Configuration: Port Security TABLE DESCRIPTION Active Select this check box to enable the port security feature on selected ports. Address Learning MAC address learning reduces outgoing broadcast traffic. For MAC address learning to occur on a port, the port itself must be active with address learning enabled. Select the Address Learning check box.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 110 Ethernet Port Configuration: Port Mirroring The following table describes the fields in this screen. Table 72 Ethernet Port Configuration: Port Mirroring LABEL DESCRIPTION Mirrored Select this option to mirror the traffic on a port. Direction Specify the direction of the traffic to mirror. Select Egress (outgoing), Ingress (incoming) or Both from the drop-down list box. Apply Click Apply to save the changes back to the switch. 16.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 111 Ethernet Port Configuration: VLAN Stacking The following table describes the fields in this screen. Table 73 Ethernet Port Configuration: VLAN Stacking LABEL DESCRIPTION Role Select Normal to have the switch ignore frames received (or transmitted) on this port with VLAN stacking tags. Anything you configure in SPVID and Priority is ignored.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 112 Ethernet Port Configuration: Queue Method The following table describes the fields in this screen. Table 74 Ethernet Port Configuration: Queue Method LABEL DESCRIPTION Q0 - Q7 For Weighted Fair Scheduling, select the queue weight here. Bandwidth is divided across the different traffic queues according to their weights. Queues with larger weights get more guaranteed bandwidth than queues with smaller weights.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 149 Chapter 16 Ethernet Port Configuration
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 17 Routing Configuration This chapter shows you how to configure the routing functions. 17.1 Static Route Static routes tell the switch how to forward IP traffic when you configure the TCP/IP parameters manually. 17.1.1 Configuring Static Routing Follow the steps below to view the Routing Configuration screen. 1 In the Device Panel list, select a device and then right-click. 2 Click Configuration, Routing Configuration.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide The following table describes the labels in the summary table. Table 75 Routing Configuration: Static Route LABEL DESCRIPTION Index This field displays the index number of the route. Name This field displays the descriptive name for this route. This is for identification purposes only. Active This field displays Yes when the static route is activated and No when is it deactivated.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 76 Routing Configuration: Static Route: Add or Modify (continued) LABEL DESCRIPTION Destination IP This parameter specifies the IP network address of the final destination. Routing is Address always based on network number. If you need to specify a route to a single host, use a subnet mask of 255.255.255.255 in the subnet mask field to force the network number to be identical to the host ID.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 153 Chapter 17 Routing Configuration
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 18 Multicast Configuration This chapter shows you how to configure multicast settings and MVR (Multicast VLAN Registration) groups. This feature is not available on all models. 18.1 Overview Refer to Section 6.3 on page 61for more background information on IGMP and IP multicast addresses. 18.1.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 115 Multicast Configuration: Multicast Setting The following table describes the labels in this screen. Table 77 Multicast Configuration: Multicast Setting 155 LABEL DESCRIPTION IGMP Snooping Select Active to enable IGMP snooping to forward group multicast traffic only to ports that are members of that group IGMP Filtering Select Active to enable IGMP filtering to control which IGMP groups a subscriber on a port can join.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 18.2.1 Changing the Port Multicast Settings To change the multicast settings of a port, select a port in the Multicast Setting screen and click Modify. A screen displays. Figure 116 Multicast Configuration: Multicast Setting: Modify The following table describes the labels in this screen. Table 78 Multicast Configuration: Multicast Setting: Modify LABEL DESCRIPTION Port This field displays the port number. Immed.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 117 Multicast Configuration: Multicast Setting: Load Template The following table describes the labels in this screen. Table 79 Multicast Configuration: Multicast Setting: Load Template LABEL DESCRIPTION Device Type Select a device type from the drop-down list box. Template No. This field displays the index number. Multicast Name This field displays the name of a multicast template you create using the Template screen.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 118 Multicast Configuration: Multicast Setting: View Profile The following table describes the labels in this screen. Table 80 Multicast Configuration: Multicast Setting: View Profile LABEL DESCRIPTION Profile Name Select a profile name from the drop-down list box. Start Address This field displays the starting multicast IP address for a range of multicast IP addresses to which you want this IGMP filter profile to allow access.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 18.3.1 Types of MVR Ports In MVR, a source port is a port on the switch that can send and receive multicast traffic in a multicast VLAN while a receiver port can only receive multicast traffic. Once configured, the switch maintains a forwarding table that matches the multicast stream to the associated multicast group. 18.3.2 MVR Modes You can set your switch to operate in either dynamic or compatible mode.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 119 Multicast Configuration: MVR The following table describes the labels in this screen. Table 81 Multicast Configuration: MVR LABEL DESCRIPTION MVLAN This table displays the settings the multicast VLAN settings. VLAN This field displays the multicast VLAN ID. Active This field displays whether the multicast group is enabled or not. Name This field displays the descriptive name for this setting.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Table 81 Multicast Configuration: MVR (continued) LABEL DESCRIPTION Add Click Add to add a new entry. Modify Click Modify to change the settings of the selected MVR. Delete Click Delete to remove the selected MVR. 18.3.4 Creating a New Multicast VLAN Follow the steps below to create a new multicast VLAN. 1 In the MVR screen, click Add under MVLAN. A screen displays as shown.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 11A screen displays showing the configuration result. Click Done to close the screen. Figure 121 Multicast Configuration: MVR: Add MVLAN: Result 18.3.5 Creating a New MVR Group Follow the steps below to create a new MVR group. 1 In the MVR screen, select one entry in the MVLAN list table. 2 Click Add under MVR Group. Figure 122 Multicast Configuration: MVR: Select MVLAN 3 A screen displays as shown.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 123 Multicast Configuration: MVR: Add 4 In the Start Address field, enter the starting IP multicast address of the multicast group in dotted decimal notation. 5 In the End Address field, enter the ending IP multicast address of the multicast group in dotted decimal notation. Enter the same IP address as the Start Address field if you want to configure only one IP address for a multicast group.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Chapter 18 Multicast Configuration 164
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 165 Chapter 18 Multicast Configuration
NetAtlas Enterprise Ethernet Switch Manager User’s Guide CHAPTER 19 Troubleshooting This chapter covers potential problems and the corresponding remedies. 19.1 Installation Problems Table 82 General Installation Problems PROBLEM CORRECTIVE ACTION The EMS or PostgreSQL will not install properly Make sure that the computer meets the minimum hardware and software requirements. See Section 1.2 on page 24 for more information. Close all programs before the installation.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 125 EMS: Remove 2 Select ZyXEL NetAtlas Enterprise V1.01 and then click Change/Remove (or Add/ Remove depending on your version of Windows). 3 Click Yes when asked to confirm removal. The Uninstall Shield now runs. 4 Click OK when the uninstall has successfully completed. Restart the computer when prompted. 19.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Appendix A SNMPc Network Manager This appendix gives a brief overview of the SNMPc Network Manager. Starting the SNMPc Network Manager You must have SNMPc properly installed before you can use the EMS; please refer to the Castle Rock web site at www.castlerock.com or see your SNMPc user's guide. You may start the SNMPc Network Manager manually or automatically each time you turn on your computer.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide SNMPc Main Window The following figure and table show the elements of the SNMPc main window. Figure 127 SNMPc Main Windows 1 5 2 3 4 Table 85 SNMPc Main Window 169 ELEMENT FUNCTION 1 Main Button Bar Buttons and controls to execute common commands quickly. Hold the cursor over an icon to see a tool tip. 2 Edit Button Bar Buttons to quickly insert map elements. Hold the cursor over an icon to see a tool tip.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Selection Tool If you can’t see the selection tool, click View, Selection Tool to display it. Use the selection tool to manipulate objects from one of several databases. Use the drag control at the right of the selection tool to change its size. Select one of the selection tool tabs to display a tree control for the database. Right-click on an icon inside a selection tree for database-specific commands.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide View Window Area The View Window Area is the main interface for viewing the SNMPc map and command results. This area uses the Multi-Document-Interface (MDI) specification to display multiple windows at the same time. Click Window and select Cascade, Tile Horizontally or Tile Vertically to rearrange the windows in the View Window Area in a way that makes them all visible.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Figure 129 SNMPc Edit Button Bar Icons Note: For more detailed information, please see www.castlerock.com.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 173 Appendix A SNMPc Network Manager
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Appendix B Alarm Types and Causes This appendix shows examples of probable alarm types and causes.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide 175 Appendix B
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Index Numerics 110V AC 4 230V AC 4 A Abnormal Working Conditions 5 AC 4 Access EMS Troubleshooting 167 Accessories 4 Acts of God 5 Airflow 4 American Wire Gauge 4 Authority 3 AWG 4 B Basement 4 C Cables, Connecting 4 Certifications 3 Changes or Modifications 3 Charge 5 Circuit 3 Class B 3 Class of Service (CoS) 142 Communications 3 Compatible MVR mode 159 Compliance, FCC 3 Components 5 Condition 5 Connecting Cables 4 Consequential Damages 5 Cont
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Electrocution 4 Element Management System 24 Equal Value 5 Europe 4 Exposure 4 F Failure 5 FCC 3 Compliance 3 Rules, Part 15 3 Federal Communications Commission 3 Finland, Contact Information 6 Fitness 5 France, Contact Information 6 Functionally Equivalent 5 G Gas Pipes 4 Germany, Contact Information 6 God, act of 5 L Labor 5 LAN Setup 98 Legal Rights 5 Liability 2 License 2 Lightning 4 Liquids, Corrosive 4 M Materials 5 Media-on-Demand (MoD) 15
NetAtlas Enterprise Ethernet Switch Manager User’s Guide Permission 2 PHB (Per-Hop Behavior) 127 Photocopying 2 Pipes 4 Pool 4 Port mirroring 125 Mirror port 125 Postage Prepaid.
NetAtlas Enterprise Ethernet Switch Manager User’s Guide U Undesired Operations 3 V Value 5 Vendor 4 Ventilation Slots 4 Viewing Certifications 3 Voltage Supply 4 Voltage, High 4 W Wall Mount 4 Warnings 4 Warranty 5 Warranty Information 6 Warranty Period 5 Water 4 Water Pipes 4 Web Site 6 Wet Basement 4 Workmanship 5 Worldwide Contact Information 6 Written Permission 2 Z Zero configuration Internet access 98 ZyNOS 2 ZyXEL Communications Corporation 2 ZyXEL Home Page 3 ZyXEL Limited Warranty Note 5 ZyXEL