User`s guide

Chapter 9 CFM Commands
Ethernet Switch CLI Reference Guide
52
9.4 Command Summary
The following section lists the commands for this feature.
Table 28 CFM Command Summary
COMMAND DESCRIPTION M P
clear ethernet cfm linktrace Clears the link trace database. E 13
clear ethernet cfm mep-ccmdb Clears the MEP CCM database. E 13
clear ethernet cfm mip-ccmdb Clears the MIP CCM database. E 13
clear ethernet cfm mep-defects Clears the MEP-defects database. E 13
ethernet cfm Enables CFM on the Switch. C 13
ethernet cfm md <md-index> format
<dns|mac|string> name <md-name>
level <0-7>
Creates an MD (Maintenance Domain) with the specified
name and level number.
md-name: Enters a domain name, MAC address or a
descriptive name for the MD.
C13
ethernet cfm ma <ma-index> format
<vid|string|integer> name <ma-name>
md <md-index> primary-vlan <1-4094>
Creates an MA (Maintenance Association) and defines
its VLAN ID under the MD. You can also define the
format which the Switch uses to send this MA information
in the domain (MD).
ma-name: Enters a VLAN ID, a descriptive name or a 2-
octet integer for the MA.
Note: If you set the format to vid, the VLAN
ID should be the same as the VLAN ID
you use to identify the MA.
C13
cc-interval
<100ms|1s|10s|1min|10min>
Sets how often an MEP sends a connectivity check
message (CCM).
C13
mhf-creation < none | default |
explicit>
Sets MHF (MIP Half Function).
Select none and no MIP can be created automatically for
this MA.
Select default to automatically create MIPs for this MA
and on the ports belonging to this MA’s VLAN when there
are no lower configured MD levels or there is an MEP at
the next lower configured MD level on the port.
Select explicit to automatically create MIPs for this
MA and on the ports belonging to this MA’s VLAN only
when there is an MEP at the next lower configured MD
level on the port.
C13
id-permission < none | chassis
| management | chassis-
management>
Sets what’s to be included in the sender ID TLV (Type-
Length-Value) transmitted by CFM packets.
Select none to not include the sender ID TLV.
Select chassis to include the chassis information.
Select management to include the management
information.
Select chassis-management to include both chassis
and management information.
C13
exit Exits from the config-ma mode. C 13
remote-mep <mep-id> Sets a remote MEP in an MA. C 13
mep <mep-id> interface port-
channel <port> direction
<up|down> priority <0-7>
Sets an MEP in an MA.
up|down: The traffic direction.
0-7: The priority value of the CCMs or LTMs transmitted
by the MEP. 1 is the lowest, then 2, 0 and 3 ~ 7.
C13