User`s guide
ZyAIR B-5000 User’s Guide
G-6 Technical Specifications
Chart G-9 INSPECTION COSMETIC AND FUNCTION
TEST ITEM TEST CONDITION CRITERIA
High Temperature
Operation
Temp.
Storage
Test
Spec.
+70 Deg. C
24 hours
Operation mode in the chamber
The same as +25 Deg. C
No Damage In
Cosmetics Or Error In
Function
Low Temperature
Operation
Temp.
Storage
Test
Spec.
-20 Deg. C
24 hours
Operation mode in the chamber
The same as +25 Deg. C
No Damage In
Cosmetics Or Error In
Function
Spec. The same as +25 Deg. C
High Temperature
High Humidity
Temp.
Humidity
Storage
Test
Spec.
+40 Deg. C
95%RH (non-condensing)
72 hours
Operation mode in room temperature 4
hours after the storage
The same as +25 Deg. C
No Damage In
Cosmetics Or Error In
Function
Temperature
Recycle
Temp.
Cycle
Test
+20→0→-20→0→+20→+40→+60→
+40→+20
Operation in the chamber 1 hour after
arriving at the test temperature
No Damage On
Electrical Or Error In
Function
ESD Discharge
By Air
Discharge
By
Contact
±15KV (Each polarity 10 times)
±8KV (Each polarity 10 times)
No Damage On
Electrical
Performance