User`s guide
ZyAIR B-5000 User’s Guide
Technical Specifications G-5
Chart G-8 CURRENT CONSUMPTION
PARAMETER TEST CONDITION SPECIFICATION TEMP. DEG. C.
Tx Current Tx continue 150mA (-48V) 25
Rx Current Rx continue 80mA (-48V) 25
Standby Current Standby 50mA (-48V) 25
RELIABILITY TEST
Chart G-9 INSPECTION COSMETIC AND FUNCTION
TEST ITEM TEST CONDITION CRITERIA
High Temperature
Operation
Temp.
Storage
Test
Spec.
+70 Deg. C
24 hours
Operation mode in the chamber
The same as +25 Deg. C
No Damage In
Cosmetics Or Error In
Function
Low Temperature
Operation
Temp.
Storage
Test
Spec.
-20 Deg. C
24 hours
Operation mode in the chamber
The same as +25 Deg. C
No Damage In
Cosmetics Or Error In
Function
High Temperature
Storage
Temp.
Storage
Test
Spec.
+80 Deg. C
24 hours
Operation mode in room temperature 4
hours after the storage
The same as +25 Deg. C
No Damage In
Cosmetics Or Error In
Function
Low Temperature
Storage
Temp.
Storage
Test:
-40 Deg. C
24 hours
Operation mode in room temperature 4
hours after the storage
No Damage In
Cosmetics Or Error In
Function