User Manual

FV828 Rev. A 02/07/23
Page 1
Important Safety Information
Do not convert or modify this Zurn product. All warranties will be voided.
All plumbing is to be installed in accordance with applicable codes and regulations.
Water supply lines must be sized to provide an adequate volume of water for each xture.
Flush all water lines prior to making connections.
Do not use pipe sealant or plumbing grease on any tting other than the control stop inlet.
Sensor units should not be located across from each other or in close proximity to highly reective surfaces.
Control stop should never be opened to allow ow greater than xture is capable of evacuating. In the event of valve failure, xture
must be able to handle a continuous ow.
Specications
Sensor Range:
12” to 60” (adjustable)
Power Type:
Battery powered; 4x C size
Operating Water Pressure:
25 psi [172 kPa] (Running); 80 Psi [552 kPa] Max (Static)
Operating Temperature:
35°F to 104°F [2°C to 40°C]
Prior to Installation
Before installing your Zurn
®
automatic sensor-equipped ush valve, the items listed below should already be installed on site:
- Closet or urinal xture
- Fixture carrier
- Drain line
- Water supply line