User Manual
FV828 Rev. A 02/07/23
Page 1
Important Safety Information
• Do not convert or modify this Zurn product. All warranties will be voided.
• All plumbing is to be installed in accordance with applicable codes and regulations.
• Water supply lines must be sized to provide an adequate volume of water for each xture.
• Flush all water lines prior to making connections.
• Do not use pipe sealant or plumbing grease on any tting other than the control stop inlet.
• Sensor units should not be located across from each other or in close proximity to highly reective surfaces.
• Control stop should never be opened to allow ow greater than xture is capable of evacuating. In the event of valve failure, xture
must be able to handle a continuous ow.
Specications
Sensor Range:
12” to 60” (adjustable)
Power Type:
Battery powered; 4x C size
Operating Water Pressure:
25 psi [172 kPa] (Running); 80 Psi [552 kPa] Max (Static)
Operating Temperature:
35°F to 104°F [2°C to 40°C]
Prior to Installation
• Before installing your Zurn
®
automatic sensor-equipped ush valve, the items listed below should already be installed on site:
- Closet or urinal xture
- Fixture carrier
- Drain line
- Water supply line