Install Instructions

FV343 Rev N 4/16/10
Page 2
PRIOR TO INSTALLATION
Prior to installing the Zurn Automatic Sensor-equipped Flushometer, install the items listed below.
All plumbing is to be installed in accordance with applicable codes and regulations.
W ater supply lines must be sized to supply an adequate volume of water for each fixture.
Flush all water lines prior to making connections.
Sensor Units should not be located across from each other or in close proximity to highly reflective surfaces.
The Zurn AquaVantage
®
valve is designed to operate over the entire pressure range recommended by plumbing fixture
manufacturers and will produce a metered flush when activated.
Protect the chrome or special finish of this AquaVantage
®
valve.Do not use toothed tools to install or service the valve.
Also, see "Care and Cleaning" section of this manual.
ZEMS6000AV-IS CLOSET
ZEMS6003AV-IS URINAL
TYPICAL INSTALLATION
RED
VDC
BLUE
GND
CAUTION:
RISK OF ELECTRIC SHOCK
DRY LOCATION USE ONLY
R
REGULATED POWER SUPPLY
PART NO : 200097001
MODEL NO : P6000-HW6
I/P : 120VAC/320mA@Full load, 60Hz
O/P : +7.6.0VDCmin@2A load
DUTY CYCLE : 2sec "On", 60sec "Off"
Delta Electronics (Thailand) Public Co.,Ltd.
7.6 VDC
OUT
BLACK
BLACK with
WHITE STRIPE
BLUE (-)
RED (+)
WHITE
BLACK
120 VAC
IN
P6000-HW6 WIRING
TO FAUCET
OR FLUSH VALVE
E323168
MADE IN THAILAND
C U S
U
L®
"Use Copper conductor only and
see details in instructioin manual"
"For Grounding Conductor, Use 18
AWG minimum"
WARNING:
To reduce risk of fire or e lectric
shock - Do not interconnect
output terminations.
RED
VDC
BLUE
GND
CAUTIO N:
RISK OF ELECTRIC SHOCK
DRY LOCATION USE ONLY
R
REGULATED POWER SUPPLY
PART NO : 200097001
MODEL NO : P6000-HW6
I/P : 120VAC/320mA@Full load, 60Hz
O/P : +7.6.0VDCmin@2A load
DUTY CYCLE : 2sec "On", 60sec "Off"
Delta Electronics (Thailand) Public Co.,Ltd.
7.6 VDC
OUT
BLACK
BLACK with
WHITE STRIPE
BLUE (-)
RED (+)
WHITE
BLACK
120 VAC
IN
P6000-HW6 WIRING
TO FAUCET
OR FLUSH VALVE
E323168
MADE IN THAILAND
C U S
U
L®
"Use Copper conductor only and
see details in instructioin manual"
"For Grounding Conductor, Use 18
AWG minimum"
WARNING:
To reduce risk of fire or electric
shock - Do not interconnect
output terminations.
HW 6 POW ER
CONVERTER
HW 6 POW ER
CONVERTER
POW ER CORD
FURNISHED
BY ZURN
MOTOR
ACTUATOR
W /SENSOR
3
4
[19]
I.P.S.
SUPPLY
FINISHED W ALL
2
1
4
[57] MIN.
4
1
4
11
1
2
[292]
4
7
16
[113]
4
3
4
±
1
2
[121±13]
3
4
[19]
VACUUM
BREAKER
TUBE
9
7
8
[251]
4
7
16
[113]
9
7
8
[251]
MOTOR
ACTUATOR
W /SENSOR
11
1
2
[292]
1
1
2
[38]
VACUUM
BREAKER
TUBE
1[25]
I.P.S.
SUPPLY
2
1
4
[57] MIN.
4
1
4
[108] MAX.
FINISHED W ALL
4
3
4
±
1
2
[121±13]
TOP OF FIXTURE
TOP OF FIXTURE
POW ER CORD
FURNISHED
BY ZURN