Install Instructions
FV343 Rev N 4/16/10
Page 2
PRIOR TO INSTALLATION
Prior to installing the Zurn Automatic Sensor-equipped Flushometer, install the items listed below.
• All plumbing is to be installed in accordance with applicable codes and regulations.
• W ater supply lines must be sized to supply an adequate volume of water for each fixture.
• Flush all water lines prior to making connections.
• Sensor Units should not be located across from each other or in close proximity to highly reflective surfaces.
The Zurn AquaVantage
®
valve is designed to operate over the entire pressure range recommended by plumbing fixture
manufacturers and will produce a metered flush when activated.
Protect the chrome or special finish of this AquaVantage
®
valve.Do not use toothed tools to install or service the valve.
Also, see "Care and Cleaning" section of this manual.
ZEMS6000AV-IS CLOSET
ZEMS6003AV-IS URINAL
TYPICAL INSTALLATION
RED
VDC
BLUE
GND
CAUTION:
RISK OF ELECTRIC SHOCK
DRY LOCATION USE ONLY
R
REGULATED POWER SUPPLY
PART NO : 200097001
MODEL NO : P6000-HW6
I/P : 120VAC/320mA@Full load, 60Hz
O/P : +7.6.0VDCmin@2A load
DUTY CYCLE : 2sec "On", 60sec "Off"
Delta Electronics (Thailand) Public Co.,Ltd.
7.6 VDC
OUT
BLACK
BLACK with
WHITE STRIPE
BLUE (-)
RED (+)
WHITE
BLACK
120 VAC
IN
P6000-HW6 WIRING
TO FAUCET
OR FLUSH VALVE
E323168
MADE IN THAILAND
C U S
U
L®
"Use Copper conductor only and
see details in instructioin manual"
"For Grounding Conductor, Use 18
AWG minimum"
WARNING:
To reduce risk of fire or e lectric
shock - Do not interconnect
output terminations.
RED
VDC
BLUE
GND
CAUTIO N:
RISK OF ELECTRIC SHOCK
DRY LOCATION USE ONLY
R
REGULATED POWER SUPPLY
PART NO : 200097001
MODEL NO : P6000-HW6
I/P : 120VAC/320mA@Full load, 60Hz
O/P : +7.6.0VDCmin@2A load
DUTY CYCLE : 2sec "On", 60sec "Off"
Delta Electronics (Thailand) Public Co.,Ltd.
7.6 VDC
OUT
BLACK
BLACK with
WHITE STRIPE
BLUE (-)
RED (+)
WHITE
BLACK
120 VAC
IN
P6000-HW6 WIRING
TO FAUCET
OR FLUSH VALVE
E323168
MADE IN THAILAND
C U S
U
L®
"Use Copper conductor only and
see details in instructioin manual"
"For Grounding Conductor, Use 18
AWG minimum"
WARNING:
To reduce risk of fire or electric
shock - Do not interconnect
output terminations.
HW 6 POW ER
CONVERTER
HW 6 POW ER
CONVERTER
POW ER CORD
FURNISHED
BY ZURN
MOTOR
ACTUATOR
W /SENSOR
3
4
[19]
I.P.S.
SUPPLY
FINISHED W ALL
2
1
4
[57] MIN.
4
1
4
11
1
2
[292]
4
7
16
[113]
4
3
4
±
1
2
[121±13]
3
4
[19]
VACUUM
BREAKER
TUBE
9
7
8
[251]
4
7
16
[113]
9
7
8
[251]
MOTOR
ACTUATOR
W /SENSOR
11
1
2
[292]
1
1
2
[38]
VACUUM
BREAKER
TUBE
1[25]
I.P.S.
SUPPLY
2
1
4
[57] MIN.
4
1
4
[108] MAX.
FINISHED W ALL
4
3
4
±
1
2
[121±13]
TOP OF FIXTURE
TOP OF FIXTURE
POW ER CORD
FURNISHED
BY ZURN