Installation Guide
FV254 Rev. F 7/10/18
Page 2 
IMPORTANT:
 • ALL PLUMBING IS TO BE INSTALLED IN ACCORDANCE 
WITH APPLICABLE CODES AND REGULATIONS.
• FLUSH ALL WATER LINES PRIOR TO INSTALLATION.
• SENSOR UNITS SHOULD NOT BE LOCATED ACROSS 
FROM EACH OTHER OR IN CLOSE PROXIMITY TO HIGHLY 
REFLECTIVE SURFACES.
1. - Cover Plate Installation
(For faucets with -CP4 or -CP8 sufx)
Remove adhesive backing from gasket and then pass sensor 
connector wire and shank through gasket. Align gasket with 
faucet bottom and press rmly together.  Pass sensor connector 
and shank through cover plate and fasten to the faucet with the 
provided screws.
3.- Electronics Module Installation
Attach sensor connector wire from the faucet to the mating sensor 
connector wire from the eletronics module. Orient connectors so that 
the pins are properly aligned before pressing connectors together.  
Do not force together, damage to pins may occur. Secure the 
cable connectors with the locking ring provided.  Be certain that 
the cable connection is made before the batteries are installed.
Attach electronics module to the shank using the hex nut and gas-
ket provided. Orient the electronics in a convenient location and 
tighten hex nut.
DO NOT USE THREAD SEALANT.
2.- Spout Installation
If there is an exsisting faucet, turn off water supply and remove the 
old faucet. Assure supply lines are completely ushed and free of 
debris.  Clean lavatory rim around the mounting area for the new 
sensor faucet.
Place the sensor connector wire and shank through cover plate 
gasket  and  hole  in  the  lavatory.    Orient  black  plastic  mounting 
washer with the slot facing up. Place mounting washer and star 
washer over shank and secure the entire assembly to the lavatory 
with the mounting nut.  The sensor wires must pass through 
slot in plastic mounting washer. *Do not pinch Sensor wires.
4a.- Battery Installation
Loosen  the  battery  cover  screw  with  the  supplied  allen  wrench.  
Remove the cover and install the batteries as indicated on the 
battery case. Replace the battery cover and secure.
4b.- ACA Plug-In Adapter Installation
When using the -ACA plug-in power supply remove sticker at loca-
tion (A) and plug in adapter.
5.- Filter or Mixing Tee or Mixing Valve Instal-
lation
The supplied inlet lter must be used with every faucet, unless a 
mixing tee or mixing valve is ordered.  The inlet lter is attached 
directly to the electronics module’s water  inlet.   Tempered water 
is then supplied to the lter using a standard 3/8” x 1/2” ball riser 
(supplied by others.)
The  optional  mixing  tee  assembly  (-MT)  or  mixing  valve  (-MV) 
have integral lters and back checks. These take the place of the 
standard inlet lter when ordered. The mixing tee or mixing valve 
outlet attaches to the electronics module with a 3/8” x 1/2” ball riser 
(supplied by others).  Hot and cold water is then supplied to the 
appropriate 3/8” compression inlets.