Install Instructions

MIXED
C
H
H
C
C
H
C
H
MIXED
SENSOR FAUCET
XL
XL
Installation Maintenance Instructions
Model ZW1070XL LEAD-FREE*
Aqua-Gard
®
Thermostatic Mixing Valve
INSTALLATION INSTRUCTIONS
It is suggested that the device be installed to deliver water to the end user.
It is to be used for the nal control of water temperature at plumbing xtures
and appliances. This ASSE 1070 approved device is to be used for point of
use. It is designed to mix cold water and hot water from the water heater
to a safer temperature range of 95-115°F (35-46°C).
1. Flush the Hot and Cold delivery lines completely before installing the
device.
2. The device can be installed in any position. Note: the inlet hot
supply is to be connected to the “H” side of the valve and the cold
supply side to the “C” side.
3. The valve is to be tted to deliver mixed water to a single outlet.
4. To set the temperature on the valve remove the protective green cap.
The cap can be removed by inserting a small blade screwdriver into the
slot at the base of the blue cap and lightly push up. Using an adjustable-
wrench or combination wrench, rotate the ats clockwise to lower
the temperature or counter-clockwise to increase the set temperature.
Read temperature with a thermometer.
5. Verify the set temperature by running a plumbing xture and reinstall
the protective plastic cap to the device. For bathroom operation set
the maximum temperature not to exceed 95-115°F (35-46°C).
PERFORMANCE
Outlet Temp. Range 95-115°F(35-46°C)
Temperature Hot Supply 120-195°F max.
(49-90.5°C)
Temperature Cold Supply 40-75°F (4.4-23.8°C)
Set Temperature Accuracy +/- 3°F(1.78°C)
Max. Working Pressure (inlet) 145 psi
Temperature must be eld set
Max. Working Pressure (Dynamic) 1.5-70 psi
Flow rate @ 45 psi pressure loss 10 gpm
Min. Flow Rate 0.35 gpm
PIPING INSTRUCTIONS
The device is designed to be installed at a single outlet. It may be used to sup-
ply individual outlets when there is sufcient supply pressure. It is suggested
to use ball valves on the Hot and Cold inlet supplies.
CAUTION: Installation of water temperature control products must be per-
formed by qualied, licensed personnel. The qualied installer should be
sure that the proper device has been selected for the proper installation. A
faulty installation can cause scalding, severe injury or death.
NOTICE: Annual inspection and maintenance is required of all
plumbing system components. To ensure proper performance and
maximum life, this product must be subject to regular inspection,
testing and cleaning.
WARNING! Water Temperatures in Excess of 122°F(50°C) Are Danger-
ous and Will Cause Scalding, Severe Injury or Death! This valve is Not
Factory preset. To deliver a safe mixed water temperature at the outlet, the
installer must use a thermometer at the outlet to verify the temperature.
Set the outlet temperature between 95°F and 115°F
INDIVIDUAL USE SINGLE USE
MODEL
INLET & OUT-
LET
DIMENSIONS (approximate)
WEIGHT
A B C
in. mm in. mm in. mm lbs. kg
38-ZW1070XLCOMP 3/8" compression 5 11/16 145 3 19/32 91 5 51/64 147 2 1
12-ZW1070XL 1/2" FNPT
5 27/64 138 3 23/64 85 5 1/4 133 2 1
12-ZW1070XLC 1/2" CU Sweat
34-ZW1070XL 3/4" FNPT
5 1/2 140 3 29/64 88 5 7/16 138 2 1
34-ZW1070XLC 3/4" CU Sweat
34-ZW1070XLCPVC 3/4" CPVC 5 27/64 138 3 3/8 86 5 9/32 134 2 1
34-ZW1070XLPEX 3/4" Barb 5 35/64 141 3 1/2 89 5 35/64 141 2 1
34-ZW1070XLM 3/4" MNPT 6 7/32 158 4 13/64 107 6 61/64 177 2 1
1-ZW1070XLC 1" CU Sweat 5 15/32 139 3 7/16 87 5 9/64 141 2 1
*This product contains a weighted average lead content less than 0.25% for wetted surfaces.
*Meets the requirements of NSF/ANSI 61-9
C
C
B
H
A
MIX
XL
WARRANTY: ZURN WILKINS Valves are guaranteed against defects of material or workmanship when used for the services recommended. If
in any recommended service, a defect develops due to material or workmanship, and the device is returned, freight prepaid, to ZURN WILKINS
within 12 months from date of purchase, it will be repaired or replaced free of charge. ZURN WILKINS’ liability shall be limited to our agreement
to repair or replace the valve only.
®
! WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov