User Manual

0,1 ±10 %4 kg
Overall dimensions ( × × ) w h d
IP20
52 90 67 х х mm
not less than 100
420
V
not more than V
Before the installation and operation
of the device, PLEASE READ BY THE END
OF THIS DOCUMENT. This will help to avoid
possible danger, mistakes and
misunderstandings
.
NON-VOLATILE STORAGE
saves all settings in the event of a power outage.
VOLTMETER
Setting the menu parameters and viewing
the voltage values stored in the memory
IS ACCOMPANIED BY THE RED LIGHT.
Measurement and power phases are determined by the
indicator and fed to the device. Zero is connected to
terminal 4.
V3 digital three-phase voltmeter (
)
hereinafter referred to
as the device is designed to monitor the voltage of a
three-phase network and the order of phase sequence.
The device stores the maximum and minimum mains
voltage in non-volatile memory. Stored values can be
reset.
2
3
To connect your device:
— take a wire;
The ambient temperature during the installation should
be within –5...+45 °С.
The appliance is intended for installation inside residences
The risk of moisture or humidity in the installation site
should be minimal.
The appliance is installed in a special box, which allows
to conduct the easy installation and operation. Cabinet
should beequipped with standard mounting rail 35 mm
width (DIN rail). The appliance takes in width of 3 standard
module on 18 mm.
The height of the appliance should be in the range
0,5...1,7 m from the floor.
— fix the appliance on the mounting rail (DIN);
For protection against short circuit and excess capacity
in circuit load necessarily need to set in front
of the appliance, the automatic circuit-breaker
schemes 1, 2 To protect person from electric shock leak is
set safety shutdown device
QF see ( ) (
).
(QD).
Terminals of the device designed for wire cross section
up to 2,5 mm². To reduce mechanical load on the terminals
it is desirable to use soft wire. Clean the end wires
of 8 ±0,5 mm. If end is longer, it can cause a short circuit,
and if short — cause unreliable connection. Use the cable
lugs. Undo the screws of the terminals and insert tipped
end of the wire in terminal. Tighten terminal with derived
average 0,5 Н·m. Low tight may lead to low contact and
overheating terminals and wires and over tight — damage
terminals and wires.
The wires are tightened in the terminals using
a screwdriver with a blade width no more than 3 mm.
The screwdriver with a blade width more than 3 mm can
cause mechanical damage to the terminals. This may
result in the loss of right for warranty.
— make the connection according to the passport.
Scheme 1. Option of wiring diagram
KV
Voltmeter
PE
PE
N
N
L
L3
L2
L1
С16
16А
QF1
40 А
QFInput
63 A
300 mA
QD
ZUBR V3
1 2 3 4
Use the «≡» button to navigate through the menu
(table 1). Use the «max» and «min» buttons to change
the parameters. After pressing the button for the first time
the parameter will flash, after pressing it for the second
time the parameter will change. After 5 sec after pressing
.return to the mains voltage display
When switched on, the device measures and displays
the effective voltage on the three phases.
To view the maximum voltage stored
in the memory, press the top button and
to view minimum voltage, press lower
button. The display of voltage values
is accompanied by the glow of dots
in the rightmost category of the screens.
To exit the view mode, press the middle button briefly
or do not use the buttons for 5 seconds.
Viewing the minimum and maximum
voltage
V3
Voltmeter for professionals
1 piece
1 piece
1 piece
Technical data sheet ,
installation and operation manual
IN THE BOX
Digital three-phase voltmeter
ZUBR V3
Technical data sheet and
installation and operation manual
and warranty card
The packing box
TECHNICAL DATA
Power Volt
Device weight
Degree of protection
GOST14254
CONNECTION SCHEMES
Scheme . Option of the connection diagram 2
L1 NL2 L3
ZUBR
V3 3x100-420 ~50 V Hz
max
L1
L1
1 2
3
4
L2
L2
L3
L3
N
reset
min
МС МС116 МС116 МС116 МС116
6000 С16 С16 С16 С16
11 33 5 7
22 44 6 8
СD 440J
1
2
3
4
5
6
N
N
40A/I n0,03A
1
2
3
4
5
6
7
8
N
T
A
N
~
РЕ
INPUT
Input
INSTALLATION
EXPLOITATION
SERVICE CENTER CONTACT
+38 (091) 481-91-81
Viber WhatsApp Telegram
support@dse.com.ua
WARRANTY CARD
place of a seal
a seller, a seal:
serial №: date of sale:
an owner contact
for a service center:
WARRANTY TERMS
The warranty for ZUBR devices is valid for
from the date of sale, provided that the instructions
are followed. The warranty period for products without
a warranty certificate is counted from the date
of production.
60 months
If your device is not working properly, we recommend that
you first read the section «Possible problems». If you
cannot find an answer, contact Service Center. In most
cases, these actions resolve all issues.
If you continue to have issues with the device, please
send it to a Service Center or to the store where you
purchased the device. If your device is defective due
to our fault, we will repair or replace it under warranty
within 14 business days.
Please see the full text of the warranty and the data
you need to send to your Service Center on the website
https://www.ds-electronics.com.ua/en/. If you have
a warranty case, please, contact the General distributor
in your area.

Summary of content (2 pages)