Tus neeg siv phau ntawv
Supply voltage (100 – 420 V, 50 Hz) served on terminals 1
and phase (L) is connected to terminal location and
the neutral conductor (N) to terminal If a circuit without
a neutral bypass through D2 is used, the neutral wire can
also be connected to terminal 4.
2, 1,
2.
The connecting wires of the load phases are connected
to the corresponding terminals (phase (L) is connected
to terminal location and zero (N) is connected to terminal
location
3, 4
3,
4).
CONNECTION SCHEMES
2
3
Scheme 1. Option of wiring diagram
with a neutral bypass through D2
INSTALLATION
The appliance is intended for installation inside residences
The risk of moisture or humidity in the installation site
should be minimal.The ambient temperature during
the installation should be within –5...+45 °С.
The appliance is installed in a special box, which allows
to conduct the easy installation and operation. Cabinet
should beequipped with standard mounting rail 35 mm
width (DIN rail). The appliance takes in width of two
standard module on 18 mm. The height of the appliance
should be in the range 0,5...1,7 m from the floor.
Terminals of the device designed for wire cross section 2
up to 16 mm². It is advisable to use a soft wire, which
is tightened in the terminals with a screwdriver with a tip
width of no more than 6 mm with a torque of 2.4 Nm.
A screwdriver with a blade more than 6 mm wide can
cause mechanical damage to the terminals. Doing so will
void your warranty claim.
For protection against short circuit and excess capacity
in circuit load necessarily need to set in front
of the appliance, the automatic circuit-breaker (QF). The
automatic switch off is established in the open-phase fault
wire, as shown at the schemes 1, 3. To protect person
from electric shock leak is set safety shutdown device.
Scheme 2 . Option of the connection diagram
with a neutral bypass through D2
Scheme 4 . Option of the connection diagram
without a neutral bypass through D2
INPUT
РЕ L N
ZUBR
input
output
TECHNICAL DATA
Model
Rated load current
(for category AC-1)
Rated power in 10 min,
(for category AC-1)
Rated power
(for category AC-1)
Voltage limit
Power Volt
Power consumption
The number of operating
cycles under load
The number of operating
cycles without load
Relay type
Connection
Device weight 0,17 ±10 %kg
not more than 16 mm
2
polarized
not less cycles 10 000
not less cycles 500 000
not more than month 0,35 /kWt
Break-time
at increasing
Break-time
at lower:
Overall dimensions
( )w h d
х х
IP to GOST 14254 IP20
36 х 85 х 66 mm
> V120
120 < V
0,1 10
0,0
– sec
not more than sec3
not less than 100
420
V
not more than V
not more than sec 0,03
upper 220–280
120–210
V
lower V
40 А 50 А
50 А
8 800 АV 11 000 АV 13 900 Аv
63 А
60 А 80 А
D2-63
D2-63 red
D2-50
D2-50 red
D2-40
D2-40 red
Before the installation and operation of the device,
PLEASE READ BY THE END OF THIS DOCUMENT.
This will help to avoid possible danger, mistakes and
misunderstandings.
All settings are stored in NON-VOLATILE MEMORY
Voltage relay 2 ZUBR D (hereinafter referred to as
the device designed to protect electrical equipment from
critical mains voltage surges. Equipment sensitive to line
voltage deviations: refrigerators, TVs, video and audio
equipment, computers, etc.
)
INPUT
РЕ L N
ZUBR
input
output
KV
Voltage relay
63 A
300 mA
QD
PE
N
L
40А
1
3
2
4
QF
input
ZUBR
D2-50
PE
N
L
Input
С16
16А
QF1
without a neutral bypass through D2
Scheme 3. Option of wiring diagram
1
3
2
4
KV
Voltage relay
63 A
300 mA
QD
PE
N
L
40А
QFinput
ZUBR
D2-50
PE
N
L
Input
С16
16А
QF1
Please see the full text of the warranty and the data you
need to send to your Service Center on the website
https://www.ds-electronics.com.ua/en/. If you have
a warranty case, please, contact the General distributor
in your area.
If your device is not working properly, we recommend that
you first read the section «Possible problems». If you
cannot find an answer, contact Service Center. In most
cases, these actions resolve all issues.
The warranty for ZUBR devices is valid for
from the date of sale, provided that the instructions are
followed. The warranty period for products without a
warranty certificate is counted from the date of production.
60 months
If you continue to have issues with the device, please
send it to a Service Center or to the store where you
purchased the device. If your device is defective due
to our fault, we will repair or replace it under warranty
within 14 business days.
WARRANTY TERMS
SERVICE CENTER CONTACT:
+38 (091) 481-91-81
Viber WhatsApp Telegram
support@dse.com.ua
place of a seal
WARRANTY CARD
serial №: date of sale:
a seller, a seal:
an owner contact
for a service center:
Technical data sheet and
installation and operation manual
Оvervoltage protection for professionals
D , D , D
D red, D 50 red, D 63 red
2-40 2-50 2-63
2-40 2- 2-
Voltage relay ZUB 2R D
Technical data sheet and
installation and operation manual
and warranty card
1 piece
1 piece
1 piece
IN THE BOX
The packing box