User Manual

Version Number: ZS-CUT50DP-20210204A1
18
11. HF works but arc starting not
good enough.
1.The Gap for tip to the metal not in
good range, The tip and electrode
damaged or oxidate.
2.HF weak because the board
leakage.
3.GAS/AIR connector damaged,
power
leakage between connector and front
panel
1.Adjust the tip to metal in right
gap .
2.Check and fix
3.Check and fix
12. HF keep sparking after press
torch switch
1.HF signal going to torch switch
board and disturb it.
1.Check the GAS/AIR torch
connector, earth female socket and
torch switch connector, if there any
HF spark between them to front
metal.
Part 10
Cutting Thickness Chart
Need to adjust the current and air pressure properly under metal thickness to get
best cutting surface.
1
ZS-CUT50DP -220V
20Amps
35Amps
40Amps
45Amps
50Amps
Thickness (mm)
5mm
8mm
10mm
12mm
15mm
Air Pressure (psi)
40-50psi
40-50psi
50-60psi
60-70psi
60-70psi
2
ZS-CUT50DP -110V
20Amps
30Amps
35Amps
Thickness (mm)
5mm
6mm
8mm
Air Pressure (psi)
40-50psi
40-50psi
50-60psi
If you are interested in translating professional local languages, please contact us at