User's Guide
Table Of Contents
- CHAPTER 1 Introduction
- CHAPTER 2 First Time Installation
- 2
- 2.1 Overview
- 2.2 System Setup
- 2.3 Configuration Step by Step
- 2.3.1 Log into ZoneDAS
- 2.3.2 Set System Time
- 2.3.3 Ensure that RF Inputs are Within Range (0 ~ 24 dBm)
- 2.3.4 Configure BU Parameters
- 2.3.5 Loading a Pre-Set Configuration with a Config File
- 2.3.6 Checking RF Activity from the BU Screen
- 2.3.7 Mount Each RU
- 2.3.8 Configure RU Parameters
- 2.3.9 Turn Service On
- 2.3.10 Fill in Descriptive Information
- 2.3.11 Set Central Management
- 2.3.12 Save Settings
- 2.3.13 Backup Configurations
- CHAPTER 3 The Web Configurator
- CHAPTER 4 Home
- Chapter 5 Setting
- Chapter 6 Fault
- CHAPTER 7 System
- CHAPTER 8 Maintenance
Chapter 4: Home
ZoneDAS User Guide Page | 31
The BU Screen
Use the BU screen to monitor the BU-RF modules’ status and input power. Click anywhere
on the Home screen’s BU illustration to open the following screen. Alternatively, click on an
RF port to do the same thing and have the bottom graph showing that particular RF port’s
activities.
Figure 26 BU Screen
The following table describes the labels on the BU screen.
Table 9 BU Screen
LABEL
DESCRIPTION
Left Side Labels
Up Time
This shows how long the BU has been operating for.
Site Name Here you may name the system’s location, for remote management.
Site Code Here you may create a code for the Site Name.
Contact
Here you may enter the contact info for your supplier or repair facility.
Right Side Labels
Graph
Click on an RF module name to have the graph below show the input power
curve for the module’s signal source (shown in yellow) and the corresponding
downlink system gain (shown in blue).
Power
Use this to control the ON/OFF status of each BU-RF module. It is possible to
power on a slot without filling it with a module, and vice versa.
Band
This displays the RF signal’s transmission frequency band.
System Gain (UL/DL)
System Gain represents the ZoneDAS system’s overall gain (BU and RU) and is
calculated as follows:
•
UL (Uplink) Gain = BU-RF port's output power - RU-RF port's input power.
•
DL (Downlink) Gain = RU-RF output power - BU-RF port's input power.
Actual Power
This is the actual measured signal strength for the signal coming into the RF
module.
Description
Enter a description or note related to this RU-RF module or its signal. Often-used
descriptions include the operator name for that signal and the frequency band
for that channel.
Buttons
Apply
Click
Apply
to save your changes to the BU’s run-time memory. The memory is
volatile and loses changes when it’s turned off or loses power, so use the Save
button on the Title Bar to save your changes to the non-volatile memory once
configuration is complete.
Cancel Click
Cancel
to lose all changes made after last clicking
Apply
.
The screen will refresh from the BU's run-time memory.
Refresh Click
Refresh