User`s guide

75 | P a g e
High Security Protocol
‘Easy Learn’ Feature
Easy Installation Via Screw Terminals.
Up to 7 Transmitters per System
Relay Outputs 5A @ 230Vac
Momentary or Latching Outputs
Robust Enclosure
FCC / CE Compliant
Range up to 100 Metres
Description
A versatile general purpose remote control, which can be used for controlling many different applications.
The system utilises the highly secure Keeloq code hopping protocol to ensure reliable operation.
Easy to install, the receiver is connected using standard ‘screw terminals’ provided. Power to the receiver is 12
or 24Vdc and the output(s) can switch up to 5A at 230Vac.
The receiver outputs operate when the transmitter switch is pressed. The outputs can be set to ‘momentary’ or
‘latching’ operation.
The system is supplied ready to ‘plug and play’, in addition a further 6 transmitters can be ‘learnt’ by the
receiver.
Remote Control System
Part Number Description
Freq
(MHz)
Range**
(Metres)
WASP-S1 Remote Control System 1 sw 433.92 100
WASP-S2 Remote Control System 2 sw 433.92 100
WASP-S3 Remote Control System 3 sw 433.92 100
Additional AM Transmitter Keyfobs
Part Number Description
HORNET-TX1 Transmitter Keyfob 1 switch
HORNET-TX2 Transmitter Keyfob 2 switch
HORNET-TX3 Transmitter Keyfob 3 switch
** Range stated is optimum, direct line of sight. In worst conditions this can be reduced.
Downloaded from Elcodis.com electronic components distributor
DSWASP-1 Feb 09 2009 Page 2
WASP HIGHLY SECURE REMOTE CONTROL SYSTEMS
Data Outputs
Each output relay provides an isolated switch. Outputs 2 to 4 Connections are Common (COM) and Normally
Open (NO) which close together when activated. Output 1 has an additional Normally Closed (NC) changeover
contact.
The action of the relay outputs is set by the Option link setting Jumper. A link is made / removed by the small
shorting link ‘cap’ placed over the pin header.
Option Link 1 Fitted = Momentary Operation
Option Link 1 Not Fitted = Latching Operation
Please Note: The relay contacts in this unit are for functional use only and must not be used for isolation
purposes
Option Links
To Learn a New Transmitter switch follow this procedure
Any transmitter button can be learnt to one or many of the receiver output relays.
Each button must be learnt to each relay individually by following this procedure:
1. Select the receiver output relay to learn to:
a. Briefly short the LRN (Learn) pins once
b. The Learn LED will flash once to indicate output relay 1 is selected