Datasheet

Datasheet
Datasheet
22/34
BD9271KUT
TSZ02201-0F1F0C100260-1-2
© 2013 ROHM Co., Ltd. All rights reserved.
27.Feb.2015 Rev.004
www.rohm.com
TSZ2211115001
MOSSHORT
(example) ERRMSK[1:0]10b (ERR MASK count08d)
Zoom (A) is the operation of ERROR detection.
(1)…When the abnormal signal MOSSHORT_ERR(internal signal) is detected, and PWM=L, the abnormal condition is detected,
ERRMSK counter starts.
(2)…When ERRMSK counter reaches to the register ERRMSK[1:0]=10b, the condition is judged to the abnormal. The internal
signal ERR_judge=H.
(3)…The external pin ERR_DET turns to ERR_DET=L within 4 clks of HSYNC.
Zoom (B) is the operation of ERROR release.
(4)…When the abnormal signal is released (MOSSHORT_ERR=L) and PWM=L, ERRMSK counter starts.
(5)…When ERRMSK counter reaches to the register ERRMSK[1:0] =10b, the condition is judged to the normal. The internal
signal ERR_judge=H.
(6)…The external pin ERR_DET turns to ERR_DET=HiZ (High as pulled up) within 4 clks of HSYNC.
Figure 19-2. Timing Chart for Error detection 2