BD9271KUT
TSZ02201-0F1F0C100260-1-2
© 2013 ROHM Co., Ltd. All rights reserved.
27.Feb.2015 Rev.004
www.rohm.com
TSZ22111・15・001
● ERROR control
There are the following four types of ERROR detection signals:
(1) LED OPEN, (2) LED SHORT, (3) REGISTER SHORT, and (4) MOS SHORT
The following section shows timing charts with the setting below:
LED OPEN
LED SHORT, REGISTER SHORT are in the same way.
(example) ERRMSK[1:0]=10b (ERR MASK count:08d)
Zoom (A) is the operation of ERROR detection.
(1)…When the abnormal signal OPEN_ERR(internal signal) is detected, and PWM=H, the abnormal condition is detected,
ERRMSK counter starts.
(2)…When ERRMSK counter reaches to the register ERRMSK[1:0]=10b, the condition is judged to the abnormal. The internal
signal ERR_judge=H.
(3)…The external pin ERR_DET turns to ERR_DET=L within 4 clks of HSYNC.
Zoom (B) is the operation of ERROR release.
(4)…When the abnormal signal is released (OPEN_ERR=L) and PWM=H, ERRMSK counter starts.
(5)…When ERRMSK counter reaches to the register ERRMSK[1:0] =10b, the condition is judged to the normal. The internal
signal ERR_judge=H.
(6)…The external pin ERR_DET turns to ERR_DET=HiZ (High as pulled up) within 4 clks of HSYNC.
HSYNC
VSYNC
OPEN_ERR
PWM
ERRMSK[1:0]
ERRMSK counter
ERR judge
ERR_DET
zoom (A)
(1) (2) (3)
Figure 19-1. Timing Chart for Error detection 1