Specifications

SARIgas Zoom Z – ZF Page
20
Rev.1
WARNING: Before making the connections it’s necessary to disconnect the power supply.
CONNECTION TO THE REGULATION CIRCUIT M2”
WITH REMOTE CONTROL (OPTIONAL) Cod.20572
CONNECTION TO THE REGULATION CIRCUIT M2”
WITH REMOTE CONTROL AND AMBIENT
THERMOSTAT (linked to the connector C-D of the
regulation cicuit “M2”)
WARNING:
Fig.26
WARNING:
Fig.27
In this type of connection, the connectors C-D must be linked
to the regulation circuit M2 and the connector C1-D1 of the
regulation circuit R2.
Warning: Connect and disconnect the circuit “R1” only after
having removed the existing electrical connection of
the combi boiler.
In this type of connection, the connector C1-D1 of the
regulation circuit R2 must be linked.
Warning: Connect and disconnect the circuit “R1” only after
having removed the existing electrical connection
of the combi boiler.
CONNECTION TO THE REGULATION CIRCUIT “M2
WITH REMOTE CONTROL AND AMBIENT
THERMOSTAT (linked to the connector C1-D1 of the
regulation circuit ”R2”)
CONNECTION TO THE REGULATION CIRCUIT “M2
WITH DAILY TIME CLOCK Cod.20573
WARNING:
Fig.28
WARNING:
Fig.29
In this type of connection, the connector C-D of the regulation
circuit “M2” must be linked.
Warning: Connect and disconnect the circuit R1” only after
having removed the existing electrical connection of
the combi boiler.
In this king of connection the cables of the time clock (M1-
M2) must be linked to the power supply of the circuit (L-N),
as indicated in the drawing.