Specifications

SARIgas Zoom Z – ZF Page
15
Rev.2
MAXIMUM LENGTHS ALLOWED FOR THE PIPING WITH "COAXIAL" AIR INTAKE EXHAUST
FUME SYSTEMS
C
12
C
32
C
42
The maximum length of the piping for the straight coaxial pipe is 3 metres for the horizontal pipe and 4 metres for the
vertical version.
With length less than 0.7 metre., a diaphragm of 46 mm must be fitted into the opening of the ventilator, which is
supplied by us (see Figs. 9-10-11 page 12.).
Coaxial exhaust flue pipes diameter 60/100 mm
Table “A”
Minimum length Maximum length
With diaphragm 46 mm
0,2 m 0,7m
Without diaphragm 0,7 m 4 m (vertical)
MAXIMUM LENGTHS ALLOWED FOR PIPING WITH "SEPARATE" AIR INTAKE EXHAUST
SYSTEMS
C
12
C
32
C
42
C
52
B
22
- The maximum length of the piping is obtained by adding the flue expulsion pipe to the length of the air suction pipe.
- The sum of the two lengths must not exceed 30 metres, each direction change reduces the available length in the
pipes by the following ratio:
For 45° angles, reduction is 0.5 metre per unit (for 80 mm pipes).
For 90° angles, reduction is 1 metre per unit (for 80 mm pipes).
Separate exhaust flue pipes, diameter 80 mm C
12
C
32
C
42
C
52
Table “B”
Minimum length Maximum length
With 46 mm. diaphragm
0,2 m +0,2 m 5 m + 5 m
Without diaphragm 5 m + 5 m 10 m + 20 m
Only exhaust flue pipe, diameter 80 mm B
22
Maximum length
With 46 mm. diaphragm
16 m
Without diaphragm 23 m
Separate exhaust flue pipes, diameter 100 mm C
12
C
32
C
42
C
52
Table “C”
Minimum length Maximum length
Without diaphragm (above 30 m) 20 m + 70 m
N.B. : the air suction pipe cannot exceed a maximum distance of 10 metres per pipe 80 mm and 20 metres for
pipes of 100 mm. In case of distances exceeding 10 metres (20 metres for the pipe 100mm) remove the
drawing on the intake hole of the comburent air (Fig.11 Ref. 5).
For a 45° bend, reduction is 0.5 metre per unit (for 100 mm pipes).
For a 90° bend, reduction is 1 metre per unit ( for 100 mm. pipes).
- The maximum lengths for the flue pipes refer to material supplied by us.
- SARIgas declines all responsibility for poor working of the boiler, damage to people and things caused by the use of
material not supplied by us.
- The condensation limit at 32°F is 5 metres. (flue outlet pipe length).
IMPORTANT: if necessary, insulate the flue outlet pipe to avoid temperature drop of the fumes along the pipes. Max.
drop allowed per metre of pipe must be less than 34°F.