Specifications

SARIgas Zoom Z – ZF Page
14
Rev.4
CONNECTION EXAMPLES OF SEPARATE PIPES FOR TYPE "C" BOILERS
(with piping of 80 mm)
This solution allows a max. length of the flue expulsion pipes plus air suction of 30 metres.
The air suction pipe however, must not exceed 10 metres in length. In case of distances exceeding 10 metres (20 metres for the
pipe 100mm) remove the drawing on the intake hole of the comburent air (Fig.11 Ref. 5).
Fig.16 C 32
Vertical outlet with elbow connector and extension pipes
Fig.17
B
22
C
52
(The pipes cannot be fitted onto opposite walls)
If the B
22
configuration boiler is installed, part
Art.00239 must be fitted to the air suction pipe
(Art.01156).
.
Wall outlets with elbow
connectors, extension pipes and
separate terminals.
Fig.19 C 42
Horizontal/Vertical flue outlet with elbow connectors and extension pipes
For the
C
42
configuration refer to EN 483 Standard, Chapter 8.2.1.4.,
paragraph "I".