Specifications
University of Pretoria etd – Combrinck, M (2006)
0.001
0.01
0.1
1
0 50 100 150 200 250 300 350 400 450 500
Depth [m]
Apparent conductivity [S/m]
Input model
SLDT: no depth factor
SLDT: depth factor 1
SLDT: depth factor 2
SLDT: depth factor 3
TEMIX 3L inversion
TEMIX 10L smooth inversion
Figure 4-20: Comparison of S-layer differential transform (SLDT) solutions using different
depth factors and layered earth inversions of synthetic data for a three layer earth (thin
conductive layer).
In the case of a thin conductive layer correction factor 3 is the most accurate of the
SLDT’s (S-layer differential transform) and also outperforms the smooth layer inversion
(Figure 4-20).
MODEL 3: Three-layer earth (thick conductive layer)
Layer Thickness Resistivity (conductivity)
1 150 m 50 ohm.m (0.02 S/m)
2 50 m 5 ohm.m (0.2 S/m)
3 inf 50 ohm.m (0.02 S/m)