Specifications

3)
Communicat ion Request
BYTE DESCRIPTION
1111 0000 Exclusive Status
0101 0010 ZOOM
ID
52H
Onnn nnnn Channel nnn nnnn
:
channel OOH-OFH or 7FH (See NOTE 1)
0000 0101 DEVICE ID 05H
:
ZOOM 9120
0001 0111 FUNCTION ID 17H
:
Communication Request
l111 0111 EOX
NOTE
:
*
Recognized only.
When this message is recognized, "Bulk Load menu" will be opened. Then the
"Completed" message will be transmitted.
If
"Bulk Load menu" can not be opened, the "Fault" message will be transmitted.
1. When this message is received on channel No. 7FH, it should be recognized on
any channel.
4)
Write Request
BYTE DESCRIPTION
1111 0000 Exclusive Status
0101 0010 ZOOM ID
52H
Onnn nnnn Channel nnn nnnn
:
channel OOH-OFH or 7FH (See NOTE 1)
0000 0101 DEVICE ID 05H
:
ZOOM 9120
0001 0010 FUNCTION ID 12H
:
Write Request
OPPP PPPP Program No. PPP PPPP
:
1
-
99
1111 0111 EOX
NOTE
:
.
*
Recognized only.
When this message is recognized
,
the Program Data in Edit Buffer will be stored
into Program memory #<Program No.
>.
Then the "Completed" message will be transmitted.
If
write operation is imcompleted, the "Fault" message will be transmitted.
l. When this message is received on channel No. "IFH,
it
should be recognized on
any channel.
MIDI page
5