Specifications
BATS AND PORTABLE BATS OPERATION
3-2
NOTE: The Hydrophone calibration data is used by the Trackman software. A set of calibration files
(included with every Hydrophone) is copied into its directory. Changing of the Hydrophone requires
that the two files that comprise the calibration factors be installed into the Trackman PC’s folder;
C:\Program Files\ORE Offshore\Trackpoint MMI\CalFiles\InUseCAL\.
The BATS Transceiver, Model 4460C, front panel is shown in Figure 3-2. The front panel contains
an ON/OFF switch and LED indicators for troubleshooting system. (The indicators are the same for
the Portable BATS Model 4461A.) The LED indicators are described as follows…
POWER
+5 When illuminated, indicates that the +5V supply is operational.
+12 When illuminated, indicates that the +12V supply is operational.
-12 When illuminated, indicates that the -12V supply is operational.
+24 When illuminated, indicates that the +24V supply is operational.
SELF TEST
When illuminated, indicates when performing its internal self test function.
TARGETS
TRIG IN (1,2,3,4) When illuminated (yellow), indicates that a trigger has been received from an
external source.
INTERR (1,2,3,4) When illuminated (green), indicates when a beacon has been interrogated,
either Internally or Externally (1, 2, 3 or 4
RECEIVE (1,2,3,4) When illuminated (red), indicates when a beacon reply has been received
from the indicated Target Acquisition Module (1, 2, 3 or 4).
5
COM PORTS
XMT (1,2,3) When illuminated (yellow), indicates that the Transceiver has Transmitted da-
ta from its COM PORT #1, 2 or 3.
RCV (1,2,3) When illuminated (green), indicates that the Transceiver has Received data
into its COM PORT #1, 2 or 3.
1PPS GPS When illuminated (yellow), indicates that the Transceiver has received the 1
PPS signal from a GPS timing sync module.
5
The LED indication will be approximately 1 interrogation cycle behind in time as all processing
/detection takes place at the end of the cycle.