Specifications

BATS AND PORTABLE BATS INSTALLATION
2-35
2.3.2 PORTABLE BATS - ETHERNET CABLE WIRING
Connect the Ethernet Cable (4450BA0133) to the Transceiver’s “ETHERNET & 1PPS” underwater
connector. See Figure 2-17. At the other end connect the “BATS LINK” cable (RJ45 Jack) to the PC.
This TCP/IP communication link configures the Transceiver (target & system parameters) using the
BATS Windows® Configuration management software, Trackman”. The Transceiver also sends
target data to the PC for further processing and display.
2.3.3 PORTABLE BATS - HYDROPHONE CABLE
Connect the Hydrophone Deck Cable Model 4113C (Figure 2-6) from the Hydrophone to the Trans-
ceiver Model 4461A.
The Deck Cable mates to the Transceiver by lining up the pins in both connectors and pushing to-
gether. The mated connection is then held together with the locking sleeves. The following are
guidelines from the manufacturer.
Align indexes on connectors and mate with minimum twisting and flexing
Care must be taken not to damage contacts in unmated connectors
Contact surfaces must be dry prior to mating.
Lubricate mating surfaces with 3M Silicone Spray or equivalent. DO NOT GREASE. Connect-
ors must be lubricated on a regular basis.
Avoid contact with solvents.
Grip main body of connector during mating or unmating. Do not pull on the cable to discon-
nect.
Avoid sharp bends at cable entry to connector.
Elastomers can be seriously degraded if exposed to direct sunlight or high ozone levels for
extended periods of time.
NOTE: Do NOT allow Silicone Spray to come in contact with the Hydrophones potting.