Specifications
BATS AND PORTABLE BATS INSTALLATION
2-18
2.2.2 BATS - ETHERNET CABLE WIRING (BETWEEN BATS & PC)
Connect the Ethernet cable (provided) between the BATS console (rear panel) and the PC. The
Ethernet cable is 10-base-T and runs at 100MHz. A straight through cable is required (cross-over is
performed inside the BATS console).
2.2.3 BATS - HYDROPHONE CABLE
Connect the Hydrophone/Interrogator Deck Cable Model 4113C-DT (Figure 2-8) from the Hydro-
phone to the Transceiver Model 4460C.
The Deck Cable mates to the Transceiver by lining up the MS connector on the CABLE with the HY-
DROPHONE input connector on the BATS unit. Thread the collar / locking sleeve down over the
bulkhead connector on the Transceiver pushing in on the connector body while turning locking
sleeve.
2.2.4 BATS – RACK MOUNT PC AND KEYBOARD/DISPLAY
2.2.4.1 VIDEO (PC TO KYBD/DISPLAY)
Connect the “Y” cable from the Processor K/M Combo connector to the Keyboard/Display Mouse
connector and Keyboard connector. The Green Keyboard/Display cable goes to the Mouse connect-
or on the Processor’s K/M Combo cable and the Blue goes to the Keyboard connector on the Pro-
cessor’s K/M Combo cable. See Figure 2-10 and 2-11.
OPTIONAL INTERFACE INTER-CONNECTS
2.2.5 BATS – COM#1 CABLE WIRING (RESERVED FOR GPS TIME, 4450A)
The COM#1 input port is only used for inputting the GPS sentences into the BATS to synchronize
the GPS time to the BATS time. Install a 9-pin (F) to 9-pin (F) communications cable between the
4460C 9-pin (M) COM1 connector to the GPS’ 9-pin (M) connector (GPS connector type may vary
between manufacturers, refer to the GPS manual for pin outs to determine if a null modem is re-
quired). See Figure 2-12 for rear panel connectors. Refer to section 3 to configure BATS for GPS
time sync.