Specifications

BATS AND PORTABLE BATS OPERATION
3-112
SYSTEM SETUP COMMAND 4
BYTE
LENGTH
DATA WORD
REPRESENTATION
RANGE
UNITS
1
1
START OF TEXT
ASCII START OF TEXT CHAR
N/A
2
1
SPACE
ASCII SPACE CHARACTER
N/A
3-5
3
MESSAGE ID
ASCII CHARACTERS "SY4"
N/A
6
1
SPACE
ASCII SPACE CHARACTER
N/A
7-13
7
ANALOG1 MIN. UNITS
ASCII
0 TO 9999.9
N/A
14
1
SPACE
ASCII SPACE CHARACTER
N/A
15-21
7
ANALOG1 MAX. UNITS
ASCII
0 TO 9999.9
N/A
22
1
SPACE
ASCII SPACE CHARACTER
N/A
23-26
4
ANALOG1 MIN. VOLTS
ASCII
0.00 to 5.99
V
27
1
SPACE
ASCII SPACE CHARACTER
N/A
28-31
4
ANALOG1 MAX. VOLTS
ASCII
0.10 to 6.00
V
32
1
SPACE
ASCII SPACE CHARACTER
N/A
33-34
2
ANALOG USE AS…
ASCII See Note below
00 to 02
N/A
35
1
SPACE
ASCII SPACE CHARACTER
N/A
36-42
7
ANALOG1 MIN. UNITS
ASCII
0 TO 9999.9
N/A
43
1
SPACE
ASCII SPACE CHARACTER
N/A
44-50
7
ANALOG1 MAX. UNITS
ASCII
0 TO 9999.9
N/A
51
1
SPACE
ASCII SPACE CHARACTER
N/A
52-55
4
ANALOG1 MIN. VOLTS
ASCII
0.00 to 5.99
V
56
1
SPACE
ASCII SPACE CHARACTER
N/A
57-60
4
ANALOG1 MAX. VOLTS
ASCII
0.10 to 6.00
V
61
1
SPACE
ASCII SPACE CHARACTER
N/A
62-63
2
ANALOG USE AS…
ASCII See Note Below
00 to 10
N/A
64
1
SPACE
ASCII SPACE CHARACTER
N/A
65-66
2
CHECKSUM
16 BIT BINARY SUM OF BYTES
N/A
N/A
67
1
SPACE
ASCII SPACE CHARACTER
N/A
68
1
CARRIAGE RETURN
ASCII CARRIAGE RETURN CHARACTER
N/A
N/A
69
1
LINEFEED
ASCII LINEFEED CHARACTER
N/A
#33 = 0
#34 = 0=Off, 1=Compass, 2=Hydrophone
#62 = 0
#63 = 0-8 represents Target #’s 1-9; 10 = Hydrophone