Specifications
BATS AND PORTABLE BATS OPERATION
3-107
3.7.2.13 TRACKMAN REMOTE INTERFACE
The Trackman Program can accept commands from a remote PC along with sending target data out
on the same port. From the DEVICE LIST select Remote Interface from the list. Set the connection
Type, the IP settings or COM port settings, and the Sentence Settings. The command “Sentence In
to Trackman” format can either be TP-SPC (EdgeTech Proprietary) or NCSC. The “Sentence Out
from Trackman” can be any of the ones from the DATA OUTPUT as shown above. (Future option.)
3.7.2.14 NCSC COMMAND STRUCTURE
The NCSC RS-232 control method uses predefined packets of information to control operational pa-
rameters. These packets are used to perform SYSTEM and TARGET setup modifications.
NOTE: The only setup that is not duplicated exactly to the NCSS specification is in the FIL-
TER LEVEL setting. The new filtering method precludes using the same five codes to
control the new filter level. A translation table takes the five codes and changes the
new filter level to a setting that is close to its original. See Target Setup Command 3
below.
The following commands are in the process of being updated to fit in with the BATS parameters.
Do not use at this time.