Specifications

BATS AND PORTABLE BATS OPERATION
3-66
BATS Beacon List setup when tracking 1 Responder with an external trigger.
Scenario: Side Scan Sonar triggers the Responder at the rate as set by the side scan sonar transmitter. Trigger output from the SSS
Transceiver goes into Trigger In 1 of BATS.
External triggering: Only Target #1 can be externally triggered. All other targets (if enabled) are forced to external trigger
mode.
Beacon 1 LED’s (Trigger-In (yel), Interrogate (grn), Receive (red)) show status.
Trigger-In 1 (External trigger) initiates interrogation of Beacon. Trigger-Out 1 signal is transmitted at the time of each interroga-
tion LED flash. Trigger Input rate must be longer than the maximum slant range to the target. E.g., A one-way travel time for a
responder at 1000m is approximately 0.7 seconds (1000 meters / 1500 meter/second = 0.66 seconds).
Num
Target
Name
Type
Serial#
Chan#
Status
Xmit
Interval
Xmt
Freq
Recv
Freq
Pulse
Width
Manual
Depth
Filter
Level
Trigger
1
Beacon1
Responder
1
Active
1
N/A
M-FSK
5
10
4
External
2
1
3
1
4
1