Specifications
BATS AND PORTABLE BATS OPERATION
3-61
To track multiple targets (simultaneously) the BATS sequences through the various reply frequen-
cies while interrogating on one frequency, or it can sequence through the interrogation frequen-
cies and receive the same reply frequency, or a combination of the two. This capability provides the
operator with the versatility to track various combinations of targets. When the BATS sees that the
same interrogation frequency has been selected for a series of targets it automatically processes
the reply frequencies from the beacon within the same interrogation cycle.
Example #1:
Transponder #1 - Interrogation Freq.: 16 kHz, Reply Freq.: M-FSK ORE-01
Transponder #2 - Interrogation Freq.: 16 kHz, Reply Freq.: M-FSK ORE-02
Transponder #3 - Interrogation Freq.: 16 kHz, Reply Freq.: M-FSK ORE-03
Transponder #4 - Interrogation Freq.: 16 kHz, Reply Freq.: M-FSK ORE-04
NOTE: If the repetition interval is set to 4 seconds, Trackman updates each transponder posi-
tion every 4 seconds.
Example #2:
Transponder #1 - Interrogation Freq.: 17 kHz, Reply Freq.: M-FSK ORE-01
Transponder #2 - Interrogation Freq.: 18 kHz, Reply Freq.: M-FSK ORE-01
Transponder #3 - Interrogation Freq.: 19 kHz, Reply Freq.: M-FSK ORE-02
Transponder #4 - Interrogation Freq.: 20 kHz, Reply Freq.: M-FSK ORE-02
3.4.1 TRANSPONDER MODE
Acoustic Transponder Mode
To establish tracking in the Transponder mode, the Transponder’s interrogation frequency must
be in the frequency band of the Hydrophone’s interrogation transducer
23
and transponder(s) must
be operational and in the water.
From the Beacon dialog box select the SETUP tab and then select Active target. Select the target
symbol that you want the target to be represented by. Enter a name for the target. From the Bea-
con ACOUSTIC PARAMETER Tab set target type to Transponder, under “Reply Parameters” select
the Reply frequency/Code and the Turn Around Time, under “Interrogation Parameters” enter the
interrogation Interval, the Interrogation Frequency/ Pulse Width or code. (This information is found
the Multibeacon Label, 4370X) Select Trigger source, internal or external. From the DEPTH tab se-
lect depth mode or enter in depth manually.
23
The interrogation transducer inside the Model 4610B hydrophone has an optimal frequency range
of 17 to 20 kHz.