Specifications

BATS AND PORTABLE BATS OPERATION
3-41
Select ANALOG when using an external sensor with an analog output. The scaling can then be
modified to be compatible with the external sensor. For example, a Model 4414B Pitch/Roll sensor.
Select SERIAL when using a sensor that outputs the data serially. For example, an NMEA format
from an EdgeTech Model 4760B MRU ($POREM output). The various formats available at the
Trackpoint (USBL) COM ports 2 or 3 are…
TSS1
TSS HHRP
PRDID
CDL/MDL
PSXN (Seatex)
POREM
Configure the Port Settings by selecting the COM Port
that the data is input to the BATS device. (COM 2 or
COM3) Next select the Port #, Baud Rate, Parity, Da-
ta Bits and Stop Bits. Note that the baud rate is lim-
ited to 38400 and the data rate is limited to 12Hz
on these ports for the Model 4460A and 100Hz
and 115.2k for Models 4460B and Model 4460C.
If the data is input via the Trackman PC then
select from the Attitude Sensor Setup box the
Trackman (PC) button. The Attitude Sensor Input
Setup box is displayed. Select COM Port button at
the top and then select the COM Port settings.
Port #, Baud Rate, Parity, Data Bits and Stop Bits.
Next select the format from the Sentence Set-
tings. The various formats available are…
POREM
POREI
TSS1
PRDID
PSXN
The data on these ports can typically be up to
115,200 baud and rates greater than 100Hz.