Installation manual

39
APPENDIX C
4/2-style Format with Sur-Gard Schedule 3A
DVACS Compatible
Updated for Version 4 Decoding
A section of the more than 2000 zones available on the MLR1 Receiver has been reserved for 4/2 Digital Dialer
Format-style printer and computer output such. The following table shows the zones reserved for 4/2-type output:
Printer Computer
Zone Message Zone Byte
01-08 ---- Alm/Rst Zn#01-08 01-08 50
09 ---- Alm/Rst Zn#09 09 51
10-17 Fire! Alm/Rst Zn#10-17 10-17 0C
18-1F Fire! Alm/Rst Zn#18-1F 18-1F 0D
20-27 Panic Alm/Rst Zn#20-27 20-27 0E
28-2F Panic Alm/Rst Zn#28-2F 28-2F 0F
30-37 Inst. Alm/Rst Zn#30-37 30-37 10
38-3F Inst. Alm/Rst Zn#38-3F 38-3F 11
40-47 Mtion Alm/Rst Zn#40-47 40-47 12
48-4F Mtion Alm/Rst Zn#48-4F 48-4F 13
50-57 24Hrs Alm/Rst Zn#50-57 50-57 14
58-5F 24Hrs Alm/Rst Zn#58-5F 58-5F 15
60-67 Tampr Alm/Rst Zn#60-67 60-67 16
68-6F Tampr Alm/Rst Zn#68-6F 68-6F 17
70-77 Delay Alm/Rst Zn#70-77 70-77 18
78-7F Delay Alm/Rst Zn#78-7F 78-7F 19
80-87 Optn1 Alm/Rst Zn#80-87 80-87 1A
88-8F Optn1 Alm/Rst Zn#88-8F 88-8F 1B
90-97 Optn2 Alm/Rst Zn#90-97 90-97 1C
98-9F Optn2 Alm/Rst Zn#98-9F 98-9F 1D
A0-A7 Optn3 Alm/Rst Zn#A0-A7 A0-A7 1E
A8-AF Optn3 Alm/Rst Zn#A8-AF A8-AF 1F
B0-B7 Fire: Alm/Rst Zn#B0-B7 B0-B7 2E
B8-BF Fire: Alm/Rst Zn#B8-BF B8-BF 2F
C0-C7 Hpres Trb/Rst Zn#C0-C7 C0-C7 34
C8-CF Lpres Trb/Rst Zn#C8-CF C8-CF 35
D0-D7 Valve Trb/Rst Zn#D0-D7 D0-D7 36
D8-DF Valve Trb/Rst Zn#D8-DF D8-DF 37
E0-E7 XXXXX Trb/Rst Zn#E0-E7 E0-E7 6C
E8-EF XXXXX Trb/Rst Zn#E8-EF E8-EF 6B
F0-FF
Do Not Use
XXXXX represents variable messages; refer
to MLR1 Library.
The following are outputs for bypasses and clearing
bypasses
Printer Computer
Zone Message Zone Byte
01-08 ---- Byp/Unb Zn#01-08 01-08 D0
09 ---- Byp/Unb Zn#09 09 D1
10-17 Fire! Byp/Unb Zn#10-17 10-17 8C
18-1F Fire! Byp/Unb Zn#18-1F 18-1F 8D
20-27 Panic Byp/Unb Zn#20-27 20-27 8E
28-2F Panic Byp/Unb Zn#28-2F 28-2F 8F
30-37 Inst. Byp/Unb Zn#30-37 30-37 90
38-3F Inst. Byp/Unb Zn#38-3F 38-3F 91
40-47 Mtion Byp/Unb Zn#40-47 40-47 92
48-4F Mtion Byp/Unb Zn#48-4F 48-4F 93
50-57 24Hrs Byp/Unb Zn#50-57 50-57 94
58-5F 24Hrs Byp/Unb Zn#58-5F 58-5F 95
60-67 Tampr Byp/Unb Zn#60-67 60-67 96
68-6F Tampr Byp/Unb Zn#68-6F 68-6F 97
70-77 Delay Byp/Unb Zn#70-77 70-77 98
78-7F Delay Byp/Unb Zn#78-7F 78-7F 99
80-87 Optn1 Byp/Unb Zn#80-87 80-87 9A
88-8F Optn1 Byp/Unb Zn#88-8F 88-8F 9B
90-97 Optn2 Byp/Unb Zn#90-97 90-97 9C
98-9F Optn2 Byp/Unb Zn#98-9F 98-9F 9D
A0-A7 Optn3 Byp/Unb Zn#A0-A7 A0-A7 9E
A8-AF Optn3 Byp/Unb Zn#A8-AF A8-AF 9F
B0-B7 Fire: Byp/Unb Zn#B0-B7 B0-B7 9E
B8-BF Fire: Byp/Unb Zn#B8-BF B8-BF 9F
C0-C7 Hpres Byp/Unb Zn#C0-C7 C0-C7 94
C8-CF Lpres Byp/Unb Zn#C8-CF C8-CF 95
D0-D7 Valve Byp/Unb Zn#D0-D7 D0-D7 96
D8-DF Other Byp/Unb Zn#D8-DF D8-DF• 97
E0-E7 Zn#E0-E7 Bypass/Unbyp. E0-E7 9C
E8-EF Zn#E8-EF Bypass/Unbyp.•• E8-EF 9B
F0-FF
Do Not Use
Notes:
Zone D8 is the default setting for Common Bypass.
•• Individual messages per zone are standard. Refer
to DVACS Line Card Alarm Decoding Version 4 for
further information.
The printer messages for zones 10 through AF can
be changed to “_____” followed by “Alm/Rst” or
“Byp/Unb” and “Zn#”.