Installation manual
35
DVAC HUB CARD AND F1/F2 OPTIONS
System and Hub Options
NOTE: If this is a new network, please configure the network in a star configuration instead of the usual cascade
arrangement as there may be up to 240 drops on the network.
Data Line Type: Schedule 3A with DVACS at 150 baud
Data String Type: 1 START + 8 DATA + 1 EVEN PARITY + 1 STOP BIT
Network Configuration: Master/Slave
Options Enabled
Lock out (L.K.) Yes
Long Transmission (L.T.) delay at 4 seconds Yes
Poll and Cut (P.C.) Yes
Count and Cut (C.C.) set at 16 Yes
F1/F2 Subset Options
EIA (L, N and X) Yes
10 mA (T1) Yes
Originate Mode (B) Yes
Normal Loop Marking (E) Yes
Continuous Carrier (K) Yes
Battery Charging (Q) No
Carrier Light (V) No
Full Duplex on master F1/F2 (D)
Half Duplex on slave F1/F2 (C)
Notes:
• RS-232 cables not necessary; cord supplied by Sur-Gard
• 12V power pack not necessary; 12VDC provided by Sur-Gard terminal equipment