17 Utility Output (Mode 04 or 05), Group B Code
When programmed as [17], the output will be activated when Mode 04 or Mode 05 is entered and any valid
Access Code assigned to Group B is keyed in.
18 Utility Output (Mode 04 or 05), Group C Code
When programmed as [18], the output will be activated when Mode 04 or Mode 05 is entered and any valid
Access Code assigned to Group C is keyed in.
19 Utility Output (Mode 04 or 05), Group D Code
When programmed as [19], the output will be activated when Mode 04 or Mode 05 is entered and any valid
Access Code assigned to Group D is keyed in.
20 Follow Chime
When programmed as [20], the output will be activated after any zone set as a “door chime” in Mode 07 is
opened.
21 Follow Buzzer
When programmed as [21], the output will be activated whenever the Keypad buzzer sounds.
22 Serial Printer Output
When programmed as [22], a serial printer may be connected to Programmable Output 1. Refer to the Serial
Printer Connection section of this manual.
23
For Future Use
24 Strobe Output
When programmed as [24], the output will be activated whenever the bell is activated, and will remain activated
until a valid code is entered.
25 30-Minute Strobe Output
When programmed as [25], the output will be activated whenever the bell is activated, and will remain activated
for 30 minutes or until a valid code is entered.
26 Bell/Siren Output for Group A
When programmed as [26], the output will be activated when the BELL output is activated during a Group A
alarm.
27 Bell /Siren Output for Group B
When programmed as [27], the output will be activated when the BELL output is activated during a Group B
alarm.
28 Bell /Siren Output for Group C
When programmed as [28], the output will be activated when the BELL output is activated during a Group C
alarm.
29 Bell /Siren Output for Group D
When programmed as [29], the output will be activated when the BELL output is activated during a Group D
alarm.
30 Follow Auto-Arm Buzzer
When programmed as [30], the output will be activated when the Auto-Arm buzzer sounds.
31 Follow Away Status
When programmed as [31], the output will be activated when any group is armed and in Away status.
32 Follow Trouble Status
When programmed as [32], the output will be activated when the “Trouble” light comes ON.
33 Follow Low Battery Status
When programmed as [33], the output will be activated when the battery voltage falls below 11.3V under load.
34 Follow Fire Status
When programmed as [34], the output will be activated when any Fire Zone is in alarm.
35 Follow AC Status
When programmed as [35], the output will be activated when an AC power failure occurs.
Programmable Output Types