Install Instructions
Form 2233-0912
MMZ3 Installation and Operating Instructions
MINI-MASTERZONE
™
ZONING SYSTEM – 3 Zones
Features
Table of Contents
Installation ……………………………………………………….2
Operation ………………………………………………………..2-3
HVAC Equipment Set-Up…………..…………………….3
Checkout..…………………………………………………………3
Wiring ………………………………………………………………3-4
Troubleshooting ………………………………………………4
INSTALLATION
The Mini-MasterZone™ Zoning System-3 is a two (2) and three (3)
zone control panel for single stage heating only, cooling only or
heating and cooling. The MMZ3 can control any single stage gas-oil-
electric furnace, hydro-air heating and air conditioning. The MMZ3
panel is the central control panel where all zone dampers, zone
thermostats, HVAC Equipment and power transformer are wired.
When installing the MMZ3 panel it is important to pick a central
location where it is most convenient to bring all the wires. Most often
this is at the furnace or air handler. It is often the most convenient
location and closest to power, the HVAC unit controls and the zone
dampers when typically located at or near the plenum.
The MMZ3 panel is made of sturdy ABS plastic and can be mounted to
any flat surface. It is recommended that the panel be mounted to a
wall or return plenum and NOT on the furnace or plenum where it will
be in contact with the high temperatures. The panel can be located in
an attic space or in an enclosed cabinet of a rooftop unit, provided the
panel enclosed and not in direct exposure to the elements.
The cover easily removes from the case by pulling firmly and separating
the cover from the case exposing the circuit board. There are 4 key-
hole mounting points in each corner of the case. The case has
openings in the rear of the case as well as the side for all wiring.
Wiring can come from the back as well as the side in order to make a
neat installation.
OPERATION
The MMZ3 can controls single stage heating and cooling HVAC
Equipment. The MMZ3 is compatible with any standard single stage
thermostat and setback thermostats as well. The MMZ3 has various
features that make installation and checkout very simple for all of the
board’s functionality.
The MMZ3’s basic function is zone control. On a call for heating or
cooling, the panel will accept the first call from any zone. Upon
accepting this call the MMZ3 will keep open the damper(s) to the zone
Zone Terminal Blocks
for Zone Damper
Motors and Zone
Thermostats
24VAC Transformer
Terminals
Re-Settable Fuse
Zone Calling Indicators
HVAC Equipment
Connections
Power Indicator LED
Boot Button
System Mode Indicator LED
Fan Operation, Sensor
and High Limit Jumpers
Leaving Air Sensor
Terminals