User's Manual

23
1) Only used during checkout “Status” LED does not illuminate
solid green when engine is running
2) Follow all General Guidelines as specified on page 6.
3) All power leads must be connected to the vehicles protected
circuitry (e.g. fuse panel, circuit breaker panel, protected
circuits). Never electrically connect Zonar equipment to
unprotected circuits. (e.g. directly to battery)
4) It is also required that all power leads (Red and White leads)
be protected with a 3 to 5 amp fuse and inline fuse holder
(included) for optimal system protection.
5) Electrical fuses should be installed as close as possible to the
source of power
5) Power Bundle wiring – 4 Pin, 3 wires
A) Red – Constant DC (+8 VDC - +30 VDC), dependent
on system type)
B) Black – Ground must be less than 1 ohm (measure from
4 Pin connector to chassis attachment point)
C) White - Switched Power
The White wire must be connected to a power source
that is active only when the engine is running or the
system will not track idle time properly
1) Engine running (+8 VDC to +30 VDC)
2) Engine NOT running (0 VDC)
3) Engine not running (key position ACC or Accessory
Mode (0 VDC)
Please contact the vehicle manufacturer for any specific
electrical questions
GPS 4 Pin Power Cable
Connect White/Red
Wires to Protected
Fused Terminal
Caution
Connect White/Red
Wires to Protected
Fused Terminal
Caution
NON-TYPICAL
SYSTEM INSTALLATION
Note: Do not follow the instructions on this page unless