User's Manual

20
Troubleshooting
Issue Possible Cause Remedy Notes
Status LED - Blinking or V2J is not detecting engine Check white lead (Switched
off - engine running RPM from ECM Power). It must have 8-
Call Zonar
Status LED - Solid - Switched power is When engine off White- Be sure to check engine
Engine off connected to an incorrect Switched power lead must off, key position ACC.
power source have 0 volts White-Switched power
lead must read 0 VDC
in this state
AUX/Alert LED solid or Internal issue Contact Zonar for a
blinking 3 minutes after replacement unit
engine start
All LEDs flashing The unit may be booting, For normal boot, give the
or receiving a Firmware unit up to 3 minutes to
update establish solid LEDs for GSM,
GPS, and Status. For a
Firmware update, give the
unit up to 25 minutes to
receive and install the
Firmware
DL1 (Jbus 1708) and/or This is normal with the None Normal Operation
DL2 (Jbus 1939) are engine running. Blinking
blinking Green at 1X per Green indicates that Jbus
second data is available from the
ECM. The DL1 and/or the
DL2 must blink green with
the engine running for the
system to work correctly
DL1 (Jbus 1708) are DL2 Engine not running Start Engine
(Jbus 1939) are both off
(Other LEDs appear to be
functioning normally)
Jbus Cable not connected Connect Jbus Cable
Jbus Cable faulty Test with known good cable
Vehicles Jbus connector Verify pinout and electrical
miswired values from manufactures
specifications
DL1 (Jbus 1708) and/or Normal Boot Sequence None Normal Operation
DL2 (Jbus 1939) are Red at
1X per second
TROUBLESHOOTING