Mount Assembly Instructions

Before fully tightening bolts, align the rack visually to remove any twist and by
measuring across the diagonals as shown. This will make the rails and modules easier
to install.
With rack aligned, tighten bolts.
* - Some rack configurations (UTRF-064,
UTRF-090 only) come with a Protector Angle.
This is a long section of steel angle that spans
between both canisters and protects the
copper tube when rail length is insufficient to
do so. If this is provided with your rack, install
it now.
Extruded Mounting Rail Installation
Description: The Zomeworks Extruded Rail is
designed to be mounted to the sliders using 3/8”
round-head, square-neck bolts. The edges of the
extrusion are different – one side has a slot to
accommodate standard 1/4” hex bolts and the other
*5/16” hex bolts (see diagram at right). When
installing rails on to the Truss Tube pay attention to
this orientation!
*- Zomeworks only provides 1/4” hardware for modules. For specific modules, 5/16”
hardware can be supplied by the customer / installer.
In order to mount the Extruded Rails in the correct spot, use a permanent marker to
layout the position of the Rail Sliders. This can be done a couple of ways:
Method 1: Find the center of the Extruded Rail. Mark lines the “Half Distance” away on
both sides of center. Refer to the table below to find the correct distance. These marks
will coincide with the centerline spacing of the Truss Tubes.
Rack Model Truss Tube
Spacing
Half
Distance
UTRF-064 42 3/4” 21 3/8”
UTRF-090 62 3/4” 31 3/8”
UTRF-120, UTRF-168 74 3/4” 37 3/8”
Method 2: Take a look at the layout drawing provided in the instruction packet. There is
a dimension showing the distance from the cut end of the Extruded Rail to the
centerline location of the Rail Slider. With the Extruded Rail in the correct orientation –