Operating Guide
3
Item Description Quantity
1 Pump 1
2 Elbow tting 1
3 Diaphram valve kit 1
4
Adapter / MPT x slip
tting
1
5 Lag bolts & washers 2 ea
6 Clamps 3
7 Venturi 1
8 Tubing 1
9 Push connect tting 1
10
Reducer bushing
tting
1
11 Float kit 1
12 Float, bracket 1
13 Foot valve 1
13
8
5
2
6
7
4
3
10
9
11
12
1
PACKAGE CONTENTS
PERFORMANCE
Pump capacity will vary due to inlet water pressure, working
water pressure, discharge elevation, number of pipe ttings,
inlet and outlet pipe size, uid viscosity, degree of water
clarity and water temperature. The ow rates in the chart are
approximate values.
NOTE: Some districts may require a reduced pressure principle
backow preventer per ASSE Standards 1013. Check local
codes.
TOTAL DYNAMIC HEAD/FLOW PER MINUTE
FLUJO POR MINUTO
15
0 20 40
5 10
0
2
5
25
8060
20
4
10
15
6
45
30
25
20
40
35
8
10
12
14
40 PSI
60 PSI
80 PSI
IL2350
TOTAL DYNAMIC HEAD
LITERS
GALLONS
PUMP PERFORMANCE
CURVE
MODEL STWB140
FEET
METERS
Model
STWB140
40 PSI 60 PSI 80 PSI
Feet Meters Gal Liters Gal Liters Gal Liters
5 1.5 12.7 48.1 19.0 72.0 20.0 75.7
10 3. 12.7 48.1 19.0 72.0 20.0 75.7
15 4.6 7.4 28.0 15.0 56.8 20.0 75.7
20 6.1 2.0 7.6 11.1 42.0 20.0 75.7
25 7.6 - - 7.1 26.9 15.3 57.9
30 9.1 - - 3.2 12.1 10.9 41.3
35 10.7 - - - - 6.4 24.2
40 12.2 - - - - 1.8 .8
Shut-o Head: 22.0 ft. (6.7m) 34.0 ft. (10.4m) 42.0 ft. (12.8m)