Operating Guide
10
Install reducer tting (2) into inlet of backup
pump (3).
Install 3/4-in. CPVC, PEX or copper pipe (5) into
(1) push-to-t connector.
Vertical Install
Install included push-to-t connector (1) into
included reducer tting (2).
(2) (1)(3)
Reducer
Fitting
Pump
Inlet
(1) (5)
3/4-in CPVC,
PEX or
copper pipe
(2) (1)
Reducer
Fitting
Push-to-fit
Connector
INSTALLATION OF SOURCE WATER PIPING
(2) (1)
Reducer
Fitting
Push-to-fit
Connector
Horizontal Installation
Install included push-to-t connector (1) into
included reducer tting (2).