Operating Guide

15
© 2020. All rights reserved.
7. Make sure your hands are dry and you are not standing
in water. Connect the pump to a properly-grounded, GFCI
electrical outlet.
WARNING: Do not use an extension cord.
NOTE: Tape the electrical cord to the discharge pipe to
prevent it from interfering with the motion of the float.
115 V
GFCI outlet
7
Hose
Clamp
Discharge
Pipe
6C
6. C. Attach mounting bracket to the discharge pipe as shown,
using hose clamp (included).
WARNING: DO NOT install high water float in direct line
of incoming water or close to the vent hole.
On level
Discharge
Pipe
Right-angle
Mounting
Bracket
6B
6. B. Position second float float at desired ‘on level’ on the
discharge pipe.
SUMP PUMP INSTALLATION (CONTINUED)