Operating Guide

5
© 2020. All rights reserved.
INSTALLATION INSTRUCTIONS
NOTE: Install the battery backup system when the
primary pump is not needed. Read instructions and
prepare all supplies before beginning installation.
1.
Disconnect power to primary sump and remove
from sump basin.
115 V
GFCI outlet
1
2. NOTE:; Before gluing any ttings, dry t all connections
to verify proper t.
Measure the distance from the ex coupling to the
existing discharge piping and cut 1-1/2-in Sched 40
PVC to this size. Install 1-1/2-in ex coupling or 1-1/2-
in union between pipe connected to the pump and the
discharge piping.
Glue all pipe and ttings once t is veried.
Measure
distance
2
3. Use the included anchors to install the
controller. For best cooling, attach to wall. The
controller must be installed at least 3 ft. above
the sump pit.
AC
POWER
FLOAT
STATUS
BATTERY
DC
PUMP
SILENCE
TEST
24/7 BASEMENT
PROTECTION
USB
RESET FLOAT
DC
PUMP
FUSE
30 AMP
by
1-800-584-8089
BasementSentry.com
DC POWER
+ 15V DC 1.6A
Controller
Anchors
Minimum
3 ft.
Sump
Basin
3