HIGH PERFORMANCE SUMP PUMP COMBO BY MODEL #STBC201 Zoeller® is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 23 BasementSentry.com MENT 24/7 BASE N PROT ECTIO ATTACH YOUR RECEIPT HERE Purchase Date Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-584-8089, 7:30 a.m. - 5:00 p.m., EST, Monday - Friday. 1 © 2020. All rights reserved.
PACKAGE CONTENTS A B C D DESCRIPTION Primary/backup pump and pipe assembly (Includes a high-capacity primary pump, back-up pump, controller, alarm system, battery charger, PVC pipe with fittings, inline check valve) Battery box Controller AC wall adapter QUANTITY 1 B D C 1 1 1 A ENT 24/7 BASEM PROTEC TION SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate, or install the product. • • • • • • • DANGER RISK OF CHEMICAL BURNS.
SAFETY INFORMATION • • • • • • • • • • • • WARNING ELECTRICAL SHOCK ALERT. Do not disassemble the motor housing. The motor has NO repairable internal parts and disassembly may cause dangerous electrical wiring issues. ELECTRICAL SHOCK ALERT. Before installing this product, have the electrical circuit checked by an electrician to ensure proper grounding. All electrical installations must conform to the National Electric Code and all local codes. ELECTRICAL SHOCK ALERT.
PREPARATION Estimated Installation Time: 1-2 hours Materials required for assembly: Basement Sentry brand deep cycle battery 1-1/2-in. Schedule 40 PVC pipe and fittings, PVC primer and glue, Phillips screw driver, hand saw PUMP 115V Primary Pump 12V Backup Pump 0 FT. 42 45 SPECIFICATIONS PERFORMANCE IN GALLONS PER MINUTE 5 FT. 10 FT. 15 38 30 12 43 35 27 28 FT. Shut Off GENERAL PUMP INFORMATION This complete system features built-in WiFi to provide mobile monitoring and alerts.
115 V GFCI outlet INSTALLATION INSTRUCTIONS NOTE: Install the battery backup system when the primary pump is not needed. Read instructions and prepare all supplies before beginning installation. 1 1. Disconnect power to primary sump and remove from sump basin. 2. NOTE:; Before gluing any fittings, dry fit all connections to verify proper fit. Measure the distance from the flex coupling to the existing discharge piping and cut 1-1/2-in Sched 40 PVC to this size.
INSTALLATION INSTRUCTIONS 4. Place the battery inside the battery box and connect the leads from the controller to the battery terminals. Connect positive (+) lead to positive terminal on the battery and black negative (-) lead to the negative battery terminal. 4 To controller NOTE: If wires are not connected properly, a loud, constant audible alarm will sound until the leads are attached to the correct terminals. 5.
INSTALLATION INSTRUCTIONS 7. Reconnect power to the primary sump pump. 7 GFCI Outlet by AC POWER FLOAT STATUS TEST 24/7 BASEMENT PROTECTION BATTERY DC PUMP SILENCE USB 1-800-584-8089 BasementSentry.com RESET FLOAT DC PUMP FUSE 30 AMP DC POWER + 15V DC 1.6A BASEMENT SENTRY CONTROLLER FUNCTIONS 1 by AC POWER FLOAT STATUS TEST BATTERY DC PUMP SILENCE USB 1-800-584-8089 BasementSentry.com 2. Test - Will run the pump to determine if amp draw of pump is within range.
BASEMENT SENTRY LED LIGHT FUNCTIONS AC POWER AC AC POWER POWER BATTERY FLOAT STATUS AC POWER DC PUMP BATTERY BATTERY BATTERY FLOAT STATUS DC PUMP CONNECTING THE CONTROLLER TO Z CONTROL® By connecting the controller to the Z Control® Cloud using the built-in WiFi, the user can set up free alert messages via email, text, and mobile app “push” notifications.
CONNECTING THE CONTROLLER TO Z CONTROL® Option 1 - Use the Mobile App (iOS and Android) (Continued) These instructions provide an overview of what the app will do. You may find additional steps needed. 1 1. O pen the app and sign in to your account, or create an account using the link at the bottom. If you do not have an account, you will need to click the link at the bottom of the home screen to create an account. Click to create account 2.
CONNECTING THE CONTROLLER TO Z CONTROL® Use the Mobile App (iOS and Android) (Continued) 4. O nce a location is created, you will need to add a device. To add a device, choose the desired location name and then touch the “+” to start adding a device. Allow access to the camera so you can scan the data matrix. 4 5. T he app will ask you to scan the data matrix QR code on the controller. You can also bypass this step and manually input the SSID of the controller, which is found on the controller label.
CONNECTING THE CONTROLLER TO Z CONTROL® Use the Mobile App (iOS and Android) (Continued) 7. Y ou can now return to the Z Control® app to find your new device set up in the location you previously selected. You can always change a device to a different location in your account. 7 8. O pen the Basement Sentry app to explore current status, configuration settings, and commands available, such as Pump Test, Buzzer Test, Silence, etc. Perform these test to be sure everything works as expected.
CONNECTING THE CONTROLLER TO Z CONTROL® Option 2 - Use your mobile device or computer to connect directly to the Basement Sentry controller Instead of using a mobile device and the Z Control® app, you can also use your mobile device or computer to directly connect to the controller. Before you begin: now what the WiFi router is named (i.e. SSID) K and password. To prevent the most common troubleshooting issues, double check to be sure you know exactly how the password is spelled, including capitalization.
CONNECTING THE CONTROLLER TO Z CONTROL® Connecting with your mobile device or computer (Continued) 2. S tanding near the controller, use your phone, tablet, or computer to look for the Basement Sentry controller SSID in your WiFi settings. It will look similar to “ZCTL_Fit_xxxx” where “xxxx” is the first 4 digits of your controller device ID. Select this, and be sure your device displays a check mark or similar indicator that you are connected to the controller local network.
CONNECTING THE CONTROLLER TO Z CONTROL® Connecting with your mobile device or computer (Continued) 4. O nce the controller LED is solid, log in to your account (or create one) at zcontrolcloud.com. 4 Click WiFi Scan button Available WiFi will show here. Choose the one you want. The controller will not connect to routers with ‘WEP’ or ‘OPEN’ security. 5. C hoose the Add New Device button next to the location you want the controller.
CONNECTING THE CONTROLLER TO Z CONTROL® Firmware Updates The Basement Sentry controller is capable of OTA, or over-the-air firmware updates. It’s possible that the controller could perform an update immediately if one is available at the Z Control® Cloud. If an update is taking place, the Z Control® LED will flicker for up to one minute while the update is downloaded. The Z Control® LED will be solid and all other LEDs will turn off while the update is being installed.
START-UP AND OPERATION 2. Check the controller. The system light should be green when the unit is plugged into a 115V outlet. 2 by AC POWER FLOAT STATUS TEST All lights will be green when plugged into 115V outlet SILENCE USB 1-800-584-8089 BasementSentry.com RESET FLOAT DC PUMP DC POWER + 15V DC 1.
START-UP AND OPERATION 5. Lift the lower (operational) float on the backup pump float switch. After one second, the backup pump will run and the alarm will sound. Be sure the inlet of the backup pump is above the inlet of the primary pump. Press ‘Silence’ for 3 seconds to cancel the alarm and reset the unit. CAUTION: Continuously running the pump dry may cause overheating and damage the pump.
START-UP AND OPERATION 8 by PLUS AC POWER FLOAT STATUS TEST 24/7 BASEMENT PROTECTION BATTERY DC PUMP FW2065 A 8. Push the ‘Silence’ button when the pump is running to turn off the alarm. The pump will continue to run for an additional ten seconds after the float has been lowered or until the controller senses water is being pumped. SILENCE USB 1-800-584-8089 BasementSentry.com 9. Press and hold the ‘Silence’ button for three seconds to reset the system and clear all faults and alarms.
CARE AND MAINTENANCE WARNING: Always disconnect pump from power source before handling. At least every three months inspect and test operation: 1.. C heck to be sure green ‘system ready’ light is on (indicates AC power is on and there are no alarm conditions) 2. Test for operation: A. U nplug primary pump and controller. Fill basin with water to the ‘on’ level of the backup pump and allow the pump to run for several minutes.
BATTERY This backup system requires a good quality, 12V battery in order to provide maximum pumping time when needed. A Basement Sentry brand battery is recommended. Otherwise, use an AGM deep-cycle 12 volt 105 amp-hour marine battery or larger. Wet cell batteries contain acid and precautions must be taken when handling. DO NOT USE gel batteries or automotive batteries. Batteries with top terminals are recommended for ease of installation.
TROUBLESHOOTING DANGER RISK OF ELECTRIC SHOCK. Always disconnect power source before attempting to install, service, or maintain the pump. Never handle a pump with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur.
WARRANTY This product is warranted for three years from the date of purchase. Subject to the conditions hereinafter set forth, the manufacturer will repair or replace to the original consumer any portion of the product which proves defective due to defective materials or workmanship. To obtain warranty service, contact the dealer from whom the product was purchased. The manufacturer retains the sole right and option to determine whether to repair or replace defective equipment, parts, or components.
COMBINACIÓN DE BOMBA DE SUMIDERO DE ALTO RENDIMIENTO BY MODELO #STBC201 Zoeller® es una marca registrada de Zoeller Co. Todos derechos reservados. BasementSentry.com MENT 24/7 BASE N PROT ECTIO ADJUNTE SU RECIBO AQUÍ Número de serie Fecha de compra ¿Preguntas, problemas, partes faltantes? Antes de acudir al minorista, llame a nuestro departamento de servicio al cliente al 1-800-584-8089, de lunes a viernes de 7:30 a.m. a 5:00 p.m., EST. 1 © 2020. Todos los derechos reservados.
CONTENIDO DEL PAQUETE DESCRIPCIÓN CANTIDAD Conjunto de bomba principal/ reserva y tubería (incluye una bomba principal de alta capacidad, bomba de reserva, controlador, sistema de alarma, cargador de batería, tubos y accesorios de PVC y una válvula de retención en línea) 1 B Caja de batería 1 C Controlador 1 D Adaptador de pared de CA 1 A B D C A ENT 24/7 BASEM PROTEC TION INFORMACIÓN DE SEGURIDAD Lea y comprenda todo el manual antes de intentar ensamblar, operar o instalar el producto.
INFORMACIÓN DE SEGURIDAD • • • • • • • • • • • ALERTA DE DESCARGA ELÉCTRICA Antes de instalar este producto, haga que un electricista revise su circuito para asegurarse de que la puesta a tierra sea adecuada. Todas las instalaciones eléctricas deben cumplir con el Código Nacional de Electricidad (NEC, por sus siglas en inglés) y con todos los códigos locales. ALERTA DE DESCARGA ELÉCTRICA.
PREPARACIÓN Tiempo estimado de ensamblaje: 1-2 horas Materiales necesarios para en ensamblaje: Batería de ciclo profundo de marca Basement Sentry, 3.8 cm (1-1/2 pulg.
115 V GFCI outlet INSTRUCCIONES DE INSTALACIÓN NOTA: instale el sistema de respaldo de batería cuando no se necesite la bomba principal. Lea las instrucciones y prepare todos los materiales antes de comenzar la instalación. 1 1. Desconecte la alimentación al sumidero principal y retírelo de la fosa del sumidero. 2. NOTA: antes de pegar cualquier conector, ajuste en seco todas las conexiones para comprobar que el acople sea correcto.
INSTRUCCIONES DE INSTALACIÓN 4. C oloque la batería dentro de la caja de batería y conecte los cables del controlador a los terminales de la batería. Conecte el cable positivo (+) al terminal positivo de la batería y el cable negro negativo (-) al terminal negativo de la batería. 4 Al controlador NOTA: si los cables no están conectados correctamente, sonará una alarma audible fuerte y constante hasta que los cables estén conectados a los terminales correctos. 5.
INSTRUCCIONES DE INSTALACIÓN 7. Vuelva a conectar la alimentación a la bomba de sumidero principal. 7 Toma de corriente GFCI by AC POWER FLOAT STATUS TEST 24/7 BASEMENT PROTECTION BATTERY DC PUMP SILENCE USB 1-800-584-8089 BasementSentry.com RESET DC PUMP FLOAT FUSE 30 AMP DC POWER + 15V DC 1.6A FUNCIONES DEL CONTROLADOR BASEMENT SENTRY by PLUS AC POWER FLOAT STATUS TEST 24/7 BASEMENT PROTECTION DC PUMP BATTERY SILENCE USB 1-800-584-8089 BasementSentry.
FUNCIONES DE LA LUZ LED DEL BASEMENT SENTRY Estado del flotador gmentos funcionan Estosjuntos segmentos para indicar funcionan la condición juntos para general indicar del lasistema. condición general del sistema.
CONECTAR EL CONTROLADOR AL Z CONTROL® Utilizar la aplicación móvil (iOS y Android) (continuación) Estas instrucciones brindan una descripción general de lo que hará la aplicación. Es posible que se necesiten pasos adicionales. 1 1. A bra la aplicación e inicie sesión en su cuenta, o cree una cuenta mediante el enlace en la parte inferior. Si no tiene una cuenta, deberá hacer clic en el enlace en la parte inferior de la pantalla de inicio para crear una. Haga clic para crear una cuenta. 2.
CONECTAR EL CONTROLADOR AL Z CONTROL® Utilizar la aplicación móvil (iOS y Android) (continuación) 4. Una vez que se haya creado una ubicación, necesitará agregar un dispositivo. Para agregar un dispositivo, elija el nombre de la ubicación deseada y luego toque el signo “+” para comenzar a agregar un dispositivo. Permita acceso a la cámara así puede escanear la matriz de datos. 5. La aplicación le pedirá que escanee el código QR de la matriz de datos en el controlador.
CONECTAR EL CONTROLADOR AL Z CONTROL® Utilizar la aplicación móvil (iOS y Android) (continuación) 7. Ahora puede regresar a la aplicación Z Control® para ver su nuevo dispositivo configurado en la ubicación que seleccionó anteriormente. Siempre puede cambiar un dispositivo a una ubicación diferente en su cuenta. 7 8. Abra la aplicación Basement Sentry para explorar el estado actual, los ajustes de configuración y los comandos disponibles, como ser Prueba de la bomba, Prueba del timbre, Silenciar, etc.
CONECTAR EL CONTROLADOR AL Z CONTROL® Opción 2 - Utilice su dispositivo móvil o computadora para conectarse al controlador Basement Sentry directamente En lugar de utilizar un dispositivo móvil y la aplicación Z Control®, también puede utilizar su dispositivo móvil o computadora para conectarse al controlador directamente. Antes de comenzar: Sepa cuál es el nombre (es decir, el SSID) y la contraseña de su router WiFi.
CONECTAR EL CONTROLADOR AL Z CONTROL® Conectarse con su dispositivo móvil o computadora (continuación) 2. Parado cerca del controlador, use su teléfono, tableta o computadora para buscar el SSID del controlador Basement Sentry en la configuración de su WiFi. Aparecerá como “ZCTL_Fit_xxxx”, donde “xxxx” son los primeros 4 dígitos del ID de su dispositivo controlador.
CONECTAR EL CONTROLADOR AL Z CONTROL® Conectarse con su dispositivo móvil o computadora (continuación) 4. Una vez que el LED del Z Control® de la APak® se quede fijo, ingrese a su cuenta (o cree una) en zcontrolcloud.com. 4 Haga clic en el botón WiFi Scan El WiFi disponible se mostrará aquí. Elija el que quiera. El controlador no se conectará a routers con seguridad “WEP” u “ABIERTA” 5. Haga clic en el botón Edit (Editar) cerca de una ubicación y seleccione “Add New Device” (Añadir nuevo dispositivo).
CONECTAR EL CONTROLADOR AL Z CONTROL® Actualizaciones de firmware: El controlador Basement Sentry admite actualizaciones de firmware OTA, o “por aire”. Es posible que el controlador pueda realizar una actualización de inmediato si hay una disponible en la nube de Z Control®. Si se está llevando a cabo una actualización, el LED de Z Control® parpadeará por hasta un minuto mientras se descarga la actualización.
ARRANQUE INICIAL Y FUNCIONAMIENTO 2. Verifique el controlador. La luz del sistema debe estar en verde cuando la unidad está conectada a una toma de corriente de 115 V. 2 by AC POWER FLOAT STATUS Todas las luces se pondrán verdes cuando se enchufe a la toma de corriente de 115 V TEST SILENCE USB 1-800-584-8089 BasementSentry.com RESET DC PUMP FLOAT DC POWER + 15V DC 1.
ARRANQUE INICIAL Y FUNCIONAMIENTO 5. Levante el flotador inferior (operativo) sobre el interruptor de flotador de la bomba de reserva. Después de un segundo, la bomba de reserva funcionará y sonará la alarma. Asegúrese de que la entrada de la bomba de reserva esté por encima de la entrada de la bomba principal. Presione Silencio durante 3 segundos para cancelar la alarma y restablecer la unidad. PRECAUCIÓN: el funcionamiento continuo de la bomba en seco puede causar sobrecalentamiento y dañar la bomba.
ARRANQUE INICIAL Y FUNCIONAMIENTO 8 by PLUS AC POWER FLOAT STATUS TEST 24/7 BASEMENT PROTECTION BATTERY DC PUMP FW2065 A 8. Pulse el botón Silencio cuando la bomba esté funcionando para apagar la alarma. La bomba continuará funcionando durante diez segundos adicionales una vez que el flotador haya descendido o hasta que el controlador detecte que se está bombeando agua. SILENCE USB 1-800-584-8089 BasementSentry.com 9.
CUIDADO Y MANTENIMIENTO ADVERTENCIA: desconecte siempre la bomba de su fuente de alimentación antes de manipularla. Al menos cada tres meses inspeccione y pruebe el funcionamiento: 1. Compruebe para asegurarse de que la luz verde de “sistema listo” está encendida (indica que la alimentación de CA está encendida y no hay condiciones de alarma) 2. Prueba de funcionamiento: A. D esenchufe la bomba principal y el controlador.
BATERÍA Este sistema de respaldo requiere una batería de 12 V de buena calidad para proporcionar el máximo tiempo de bombeo cuando sea necesario. Se recomienda un cargador de marca Basement Sentry. De lo contrario, use una batería marina AGM de ciclo profundo de 12 voltios y 105 amp-hora o más grande. Las baterías húmedas contienen ácido y hay que tener precaución al manipularlas. NO USE baterías de gel o baterías automotrices. Se recomiendan baterías con terminales superiores para facilitar la instalación.
SOLUCIÓN DE PROBLEMAS PELIGRO RIESGO DE DESCARGA ELÉCTRICA. Siempre desconecte la fuente de alimentación antes de intentar instalar, reparar o mantener la bomba. Nunca manipule una bomba con las manos mojadas o cuando esté parado sobre una superficie mojada o húmeda o en el agua. Podría producirse una descarga eléctrica mortal..
GARANTÍA Este producto se garantiza por un período de tres años a partir de la fecha de compra. Sujeto a las condiciones indicadas a continuación, el fabricante se compromete a reparar o reemplazar al consumidor original cualquier parte del producto que resulte defectuosa debido a defectos de materiales o mano de obra. Para obtener el servicio de garantía, póngase en contacto con el distribuidor al que le compró el producto.