Operating Guide
6
© 2020. All rights reserved.
4. Slide the included stainless steel clamp over the
check valve and slide the tee (slit end down)
over the check valve. Be sure the o-ring is
completely covered. Tighten clamp over the tee
to secure the check valve.
5. NOTE: Before gluing any ttings, dry t all
connections to verify proper t.
Measure the connection from the Tee to
discharge piping and cut 1-1/2-in Sched 40
PVC to this size. Install 1-1/2-in ex coupling or
1-1/2-in union between pipe connected to the
pump and the discharge piping. Glue all pipe
and ttings once t is veried.
6. To Install the dual oat assembly on discharge
piping, locate the oat assembly so the ‘on’
level of the lower oat is above the ‘on’ position
of the primary pump. Use the included bracket
and stainless steel clamp to attach the oat to
the pipe. Tighten the clamp in place. Be sure
the oats are free to move up and down without
any interference from any part of the sump
pump system or basin.
Clamp
Mounting
Bracket
6
Measure
distance
1-1/2-in flex
coupling or
union
Check valve
assembly
Clamp
Tee
Backup
Pump
O-Ring
Weep hole
4
INSTALLATION INSTRUCTIONS
5