AUTOMATIC EMERGENCY BACKUP SUMP PUMP SYSTEM BY MODEL #STBB300 Zoeller® is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 25 BasementSentry.com ATTACH YOUR RECEIPT HERE Purchase Date Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-584-8089, 7:30 a.m. - 5:00 p.m., EST, Monday - Friday. 1 © 2020. All rights reserved.
PACKAGE CONTENTS A B C D E F G DESCRIPTION 12V Pump with o-ring Controller/charger Dual Float Check Valve with o-ring Tee Fitting Pipe Clamps Battery Box QUANTITY 1 1 1 1 1 2 1 G B A C E D F SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate, or install the product. • • • • • • • DANGER RISK OF CHEMICAL BURNS. Battery acid is corrosive. Do not spill on skin, clothing or battery charger. Wear eye and head protection when working with battery.
SAFETY INFORMATION • • • • • • • • • • • • WARNING ELECTRICAL SHOCK ALERT. Do not disassemble the motor housing. The motor has NO repairable internal parts and disassembly may cause dangerous electrical wiring issues. ELECTRICAL SHOCK ALERT. Before installing this product, have the electrical circuit checked by an electrician to ensure proper grounding. All electrical installations must conform to the National Electric Code and all local codes. ELECTRICAL SHOCK ALERT.
PREPARATION Estimated Installation Time: 2-4 hours Materials required for assembly: Basement Sentry brand deep cycle battery, 1-1/2-in. Schedule 40 PVC pipe, PVC primer and glue, 1-1/2-in flex coupling and clamps or 1-1/2-in. union. MODEL STBB300 0 FT. 45 SPECIFICATIONS PERFORMANCE IN GALLONS PER MINUTE 5 FT. 10 FT. 15 43 35 27 28 FT. Shut Off GENERAL PUMP INFORMATION This system features built-in WiFi to provide mobile monitoring and alerts.
115 V GFCI outlet INSTALLATION INSTRUCTIONS NOTE: Install the battery backup system when the primary pump is not needed. Read instructions and prepare all supplies before beginning installation. 1 1. Disconnect power to primary sump and remove from sump basin. 2. Be sure the o-ring is on the discharge of the backup pump and slip the included stainless steel clamp over the pump discharge. Press the backup pump into the tee. Be sure the o-ring is completely inside the tee and not visible.
INSTALLATION INSTRUCTIONS 4. S lide the included stainless steel clamp over the check valve and slide the tee (slit end down) over the check valve. Be sure the o-ring is completely covered. Tighten clamp over the tee to secure the check valve. 4 Backup Pump Tee Clamp O-Ring Check valve assembly Weep hole 5. NOTE: Before gluing any fittings, dry fit all connections to verify proper fit. 5 Measure the connection from the Tee to discharge piping and cut 1-1/2-in Sched 40 PVC to this size.
INSTALLATION INSTRUCTIONS 7. U se the included anchors to install the controller. For best cooling, attach to wall. The controller must be installed at least 3 ft. above the sump pit. 7 Anchors by AC POWER FLOAT STATUS TEST 24/7 BASEMENT PROTECTION BATTERY DC PUMP SILENCE USB 1-800-584-8089 BasementSentry.com RESET FLOAT DC PUMP FUSE 30 AMP DC POWER + 15V DC 1.6A Controller Minimum 3 ft. Sump Basin 8.
INSTALLATION INSTRUCTIONS 10.Plug the controller into a GFCI-protected 115V outlet. 10 GFCI Outlet by AC POWER FLOAT STATUS TEST 24/7 BASEMENT PROTECTION BATTERY DC PUMP SILENCE USB 1-800-584-8089 BasementSentry.com Test for backup pump operation by adding water to the sump basin. 11. Reconnect power to the primary sump pump by plugging the primary sump pump into the outlet on the front of the controller.This will will enable the controller and app to monitor the primary sump pump.
BASEMENT SENTRY CONTROLLER FUNCTIONS 1 by PLATINUM AC POWER FLOAT STATUS TEST 24/7 BASEMENT PROTECTION BATTERY DC PUMP FW2065 A There are two buttons on the front of the controller. 1. Silence/Reset - Can be pressed to silence current alarms for 24 hours. Can be held for 3+ seconds to reset (or clear) alarms and LEDs. Flashing LEDs for conditions such as bad/ disconnected battery or power outage, for example, can’t be cleared by Silence/Reset.
CONNECTING THE CONTROLLER TO Z CONTROL® By connecting the controller to the Z Control® Cloud using the built-in WiFi, the user can set up free alert messages via email, text, and mobile app “push” notifications. In addition, the user can verify controller readiness, remotely silence alarms and reset the unit, configure settings, and modify how notifications are sent. Other visual information such as input status and battery level are available through the web and app interfaces.
CONNECTING THE CONTROLLER TO Z CONTROL® Use the Mobile App (iOS and Android) (Continued) 2 2. Open your profile to set up any additional phone numbers or email addresses where notifications should be sent. 3. Once you’re logged in to your account, create locations by touching the “+ “ from the Locations screen. 3 Touch + to create locations 4. Once a location is created, you will need to add a device. To add a device, choose the desired location name and then touch the “+” to start adding a device.
CONNECTING THE CONTROLLER TO Z CONTROL® Use the Mobile App (iOS and Android) (Continued) 5 Click to manually input SSID 5. T he app will ask you to scan the data matrix QR code on the controller. You can also bypass this step and manually input the SSID of the controller, which is found on the controller label. 6.
CONNECTING THE CONTROLLER TO Z CONTROL® Use the Mobile App (iOS and Android) (Continued) 8 8. O pen the Basement Sentry app to explore current status, configuration settings, and commands available, such as Pump Test, Buzzer Test, Silence, etc. Perform these test to be sure everything works as expected. Reset all alarms when you are finished.
CONNECTING THE CONTROLLER TO Z CONTROL® Connecting with your mobile device or computer (Continued) pply AC power to the controller. The Z A Control® LED will blink and then turn off, indicating the controller is in AP Mode* and is transmitting an SSID. If the LED is blinking and not in AP mode, press the Z Control® button for 12 seconds and let go. by PLATINUM AC POWER FLOAT STATUS TEST 24/7 BASEMENT PROTECTION BATTERY The LED will now be off, indicating the controller is in AP Mode.
CONNECTING THE CONTROLLER TO Z CONTROL® Connecting with your mobile device or computer (Continued) 3. O n the setup screen, press the WiFi Scan button, scroll down to see the list of WiFi signals found, and choose the WiFi you want the Basement Sentry controller to use for internet connectivity. Enter the password for the router you chose in the field indicated. If the password is correct, the controller will connect to the router and start sending status updates to zcontrolcloud.com.
CONNECTING THE CONTROLLER TO Z CONTROL® Connecting with your mobile device or computer (Continued) 5. Choose the Add New Device button next to the location you want the controller. Follow the directions to add your controller by either auto-detect or entering the Device I.D. When successful, a Basement Sentry product tile will appear in your account. 5 Firmware Updates LED will be solid and all other LEDs will turn off while the update is being installed.
START-UP AND OPERATION 1. WARNING: Disconnect the primary pump from the 115V outlet before touching any component in the sump basin. 1 by AC POWER FLOAT STATUS TEST 24/7 BASEMENT PROTECTION BATTERY DC PUMP SILENCE USB 1-800-584-8089 BasementSentry.com RESET FLOAT DC PUMP FUSE 30 AMP DC POWER + 15V DC 1.6A Test the installation for leaks by running water into the sump basin. The primary pump should operate normally. 2. Check the controller.
START-UP AND OPERATION • • The following LED functions provide a visual cue to the proper function of the DC pump: The DC pump LED will stay yellow after pumping water, alerting you when the DC pump has turned on and has pumped water. If the DC pump runs and does not pump water, the LED will not stay yellow. This can occur during a test of the system when the float is lifted manually while the pump is above the water line. This allows the system to be tested without having to reset it each time.
START-UP AND OPERATION 7. Complete the final test of the installation. Be sure the primary pump is still disconnected from power. Unplug the controller from the 115V outlet. Run water into the sump basin until the backup pump turns on. Check all connections for leaks. 7 8. Push the ‘Silence’ button when the pump is running to turn off the alarm. The pump will continue to run for an additional ten seconds after the float has been lowered or until the controller senses water is being pumped.
START-UP AND OPERATION 10. Connect the controller AC power and primary pump into the receptacle on the front of the controller. Fill basin with water to ensure primary pump functions normally. 10 11. The four circle LED’s will be blue when charging the battery. The battery LED will flash slowly. Once charging is complete, all four circle LED’s will turn green. 11 by AC POWER FLOAT STATUS TEST 24/7 BASEMENT PROTECTION BATTERY DC PUMP SILENCE USB 1-800-584-8089 BasementSentry.
CARE AND MAINTENANCE WARNING: Always disconnect pump from power source before handling. At least every three months inspect and test operation: 1.. C heck to be sure green ‘system ready’ light is on (indicates AC power is on and there are no alarm conditions) 2. Test for operation: A. U nplug primary pump and controller. Fill basin with water to the ‘on’ level of the backup pump and allow the pump to run for several minutes.
BATTERY This backup system requires a good quality, 12V battery in order to provide maximum pumping time when needed. A Basement Sentry brand battery is recommended. Otherwise, use an AGM deep-cycle 12 volt 105 amp-hour marine battery or larger. Wet cell batteries contain acid and precautions must be taken when handling. DO NOT USE gel batteries or automotive batteries. Batteries with top terminals are recommended for ease of installation.
TROUBLESHOOTING DANGER RISK OF ELECTRIC SHOCK. Always disconnect power source before attempting to install, service, or maintain the pump. Never handle a pump with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur.
WARRANTY This product is warranted for three years from the date of purchase. Subject to the conditions hereinafter set forth, the manufacturer will repair or replace to the original consumer any portion of the product which proves defective due to defective materials or workmanship. To obtain warranty service, contact the dealer from whom the product was purchased. The manufacturer retains the sole right and option to determine whether to repair or replace defective equipment, parts, or components.
EMERGENCIA AUTOMÁTICA SISTEMA DE BOMBA DE SUMIDERO DE RESERVA BY MODELO #STBB300 Zoeller® es una marca registrada de Zoeller Co. Todos derechos reservados. BasementSentry.com ADJUNTE SU RECIBO AQUÍ Fecha de compra ¿Preguntas, problemas, partes faltantes? Antes de acudir al minorista, llame a nuestro departamento de servicio al cliente al 1-800-584-8089, de lunes a viernes de 7:30 a.m. a 5:00 p.m., EST. 1 © 2020. Todos los derechos reservados.
PACKAGE CONTENTS DESCRIPCIÓN CANTIDAD A Bomba de 12 V con junta tórica 1 B Controlador/cargador C Flotador doble 1 1 D F Válvula de retención con junta tórica Conector en T 1 F Abrazaderas para tubería 2 G Caja de batería 1 G B 1 A C E D F INFORMACIÓN DE SEGURIDAD Lea y comprenda completamente este manual antes de intentar ensamblar, usar o instalar el producto. • • • • • • • PELIGRO RIESGO DE QUEMADURAS QUÍMICAS. El ácido de batería es corrosivo.
INFORMACIÓN DE SEGURIDAD • • • • • • • • • • • ALERTA DE DESCARGA ELÉCTRICA. Antes de instalar este producto, haga que un electricista revise su circuito para asegurarse de que la puesta a tierra sea adecuada. Todas las instalaciones eléctricas deben cumplir con el Código Nacional de Electricidad (NEC, por sus siglas en inglés) y con todos los códigos locales. ALERTA DE DESCARGA ELÉCTRICA.
PREPARACIÓN Tiempo estimado de instalación 2-4 horas Materiales necesarios para en ensamblaje: Batería de ciclo profundo de marca Basement Sentry de 3.8 cm (1-1/2 pulg.). Tubería PVC 40 Imprimación y pegamento de PVC, acoplamiento flexible de 3.8 cm (1-1/2 pulg.) y abrazaderas o unión de 3.8 cm (1-1/2 pulg.).
115 V GFCI outlet INSTRUCCIONES DE INSTALACIÓN NOTA: instale el sistema de reserva a batería cuando no se necesite la bomba principal. Lea las instrucciones y prepare todos los materiales antes de comenzar la instalación. 1 1. Desconecte la alimentación al sumidero principal y retírelo de la fosa del sumidero.. 2. Asegúrese de que la junta tórica esté en la descarga de la bomba de reserva y deslice la abrazadera de acero inoxidable incluida sobre la descarga de la bomba.
INSTRUCCIONES DE INSTALACIÓN 4. D eslice la abrazadera de acero inoxidable incluida sobre la válvula de retención y deslice la T (extremo de hendidura hacia abajo) sobre la válvula de retención. Asegúrese de que la junta tórica esté completamente cubierta. Apriete la abrazadera sobre la T para asegurar la válvula de retención. 4 Bomba de reserva T Abrazadera Junta tórica Conjunto de válvula de retención Orificio de drenaje 5.
INSTRUCCIONES DE INSTALACIÓN 7. U se los anclajes incluidos para instalar el controlador. Para un mejor enfriamiento, adhiéralo a la pared. El controlador debe instalarse al menos a 2.7 m (3 pies) por encima de la fosa del sumidero. 7 Anclajes by AC POWER FLOAT STATUS TEST 24/7 BASEMENT PROTECTION BATTERY DC PUMP SILENCE USB 1-800-584-8089 BasementSentry.com RESET FLOAT DC PUMP FUSE 30 AMP DC POWER + 15V DC 1.6A Controlador Mínimo de 2.7 m (3 pies) Contenedor para agua de sumidero 8.
INSTRUCCIONES DE INSTALACIÓN 10. Enchufe el controlador en una toma de corriente de 115 V protegida por GFCI. 10 Toma de corriente GFCI by AC POWER FLOAT STATUS TEST 24/7 BASEMENT PROTECTION BATTERY DC PUMP SILENCE Pruebe el funcionamiento de la bomba de reserva agregando agua al contenedor para agua de sumidero. USB 1-800-584-8089 BasementSentry.com 11. Vuelva a conectar la alimentación a la bomba de sumidero principal enchufando en el receptáculo en la parte frontal del controlador.
FUNCIONES DEL CONTROLADOR BASEMENT SENTRY Hay dos botones en la parte frontal del controlador. 1. Silencio/Restablecer - Se puede presionar para silenciar las alarmas actuales por 24 horas. 1 by AC POWER Prueba FLOAT STATUS TEST 24/7 BASEMENT PROTECTION SILENCE Silencio / Restablecer USB 1-800-584-8089 BasementSentry.com RESET DC PUMP FLOAT FUSE 30 AMP 2 by PLATINUM AC POWER Prueba FLOAT STATUS TEST 24/7 BASEMENT PROTECTION BATTERY DC PUMP SILENCE FW2065 A 2.
CONECTAR EL CONTROLADOR AL Z CONTROL® Al conectar el controlador a la nube del Z Control® mediante el WiFi integrado, el usuario puede configurar mensajes de alerta gratuitos por correo electrónico, mensajes de texto y notificaciones “push” de la aplicación móvil. Además, el usuario puede verificar la disponibilidad del controlador, silenciar alarmas y restablecer la unidad de manera remota, ajustar las configuraciones y modificar la forma de envío de las notificaciones.
CONECTAR EL CONTROLADOR AL Z CONTROL® Utilizar la aplicación móvil (iOS y Android) (continuación) 2. A bra su perfil para configurar números de teléfono o direcciones de correo electrónico adicionales donde se deberían enviar las notificaciones. 3. U na vez que haya iniciado sesión en su cuenta, cree ubicaciones tocando el signo “+” desde la pantalla Ubicaciones. 2 3 Toque + para crear ubicaciones 4. U na vez que se haya creado una ubicación, necesitará agregar un dispositivo.
CONECTAR EL CONTROLADOR AL Z CONTROL® Utilizar la aplicación móvil (iOS y Android) (continuación) 5. L a aplicación le pedirá que escanee el código QR de la matriz de datos en el controlador. Puede omitir este paso e ingresar manualmente el SSID del controlador, que se encuentra en la etiqueta del controlador. 6.
CONECTAR EL CONTROLADOR AL Z CONTROL® Utilizar la aplicación móvil (iOS y Android) (continuación) 8 8. A bra la aplicación Basement Sentry para explorar el estado actual, los ajustes de configuración y los comandos disponibles, como ser Prueba de la bomba, Prueba del timbre, Silenciar, etc. Realice estas pruebas para garantizar que todo funciona como es debido. Restablezca todas las alarmas cuando termine.
CONECTAR EL CONTROLADOR AL Z CONTROL® Conectarse con su dispositivo móvil o computadora (continuación) C onecte el controlador a la alimentación de CA. El LED del Z Control® parpadeará y luego se apagará, indicando que el controlador está en modo AP* y está transmitiendo el SSID. by PLATINUM AC POWER FLOAT STATUS TEST 24/7 BASEMENT PROTECTION Si el LED parpadea pero no está en modo AP, presione el botón del Z Control® durante 12 segundos y suéltelo.
CONECTAR EL CONTROLADOR AL Z CONTROL® Conectarse con su dispositivo móvil o computadora (continuación) 3. E n la pantalla de configuración, presione el botón “WiFi Scan” (Escanear WiFi), deslícese hacia abajo para ver la lista de señales de WiFi encontradas y elija el WiFi que quiere usar para que el controlador Basement Sentry tenga conexión a Internet. Ingrese la contraseña del router que eligió en el campo indicado.
CONECTAR EL CONTROLADOR AL Z CONTROL® Conectarse con su dispositivo móvil o computadora (continuación) 5. Elija el botón “Add New Device” (Agregar dispositivo nuevo) junto a la ubicación donde quiere al controlador (ver figura D). Siga las instrucciones para agregar su controlador, ya sea a través de la detección automática o el ingreso del ID del dispositivo. Cuando lo haya logrado, aparecerá en su cuenta la ficha del producto Basement Sentry.
ARRANQUE INICIAL Y FUNCIONAMIENTO 1. ADVERTENCIA: desconecte la bomba principal de la toma de corriente de 115 V antes de tocar cualquier componente en el contenedor para agua de sumidero. 1 by AC POWER FLOAT STATUS TEST 24/7 BASEMENT PROTECTION BATTERY DC PUMP SILENCE USB 1-800-584-8089 BasementSentry.com RESET FLOAT DC PUMP FUSE 30 AMP DC POWER + 15V DC 1.6A Pruebe que la instalación no tenga fugas al alimentar agua al contenedor para agua de sumidero.
ARRANQUE INICIAL Y FUNCIONAMIENTO • Si la bomba de CC funciona y no bombea agua, el LED no permanecerá amarillo. Esto puede ocurrir durante una prueba del sistema cuando el flotador se levanta manualmente mientras la bomba está por encima de la línea de agua. Esto permite probar el sistema sin tener que reiniciarlo cada vez. 4 Luz verde fija cuando está cargada by PLATINUM AC POWER FLOAT STATUS TEST 24/7 BASEMENT PROTECTION BATTERY DC PUMP SILENCE FW2065 A 4.
ARRANQUE INICIAL Y FUNCIONAMIENTO 7. Complete la prueba final de la instalación. Asegúrese de que la bomba principal aún esté desconectada de la alimentación. Desenchufe el controlador de la toma de corriente de 115 V. Deje correr el agua hacia el contenedor para agua de sumidero hasta que se encienda la bomba de reserva. Revise todas las conexiones por si hay fugas. 7 8. Pulse el botón Silencio cuando la bomba esté funcionando para apagar la alarma.
ARRANQUE INICIAL Y FUNCIONAMIENTO 10.Conecte la alimentación de CA del controlador y la bomba principal en el receptáculo en la parte frontal del controlador. Llene el contenedor con agua para asegurar que la bomba primaria funcione normalmente. 10 11. Los cuatro LED del círculo estarán azules cuando la batería se esté cargando. El LED de la batería parpadeará lentamente. Una vez que se completa la carga, los cuatro LED del círculo se volverán verdes.
CUIDADO Y MANTENIMIENTO ADVERTENCIA: desconecte siempre la bomba de su fuente de alimentación antes de manipularla. Al menos cada tres meses inspeccione y pruebe el funcionamiento: 1. Compruebe para asegurarse de que la luz verde de “sistema listo” está encendida (indica que la alimentación de CA está encendida y no hay condiciones de alarma) 2. Prueba de funcionamiento: A. D esenchufe la bomba principal y el controlador.
BATERÍA Este sistema de reserva requiere una batería de 12 V de buena calidad para proporcionar el máximo tiempo de bombeo cuando sea necesario. Se recomienda una batería de la marca Basement Sentry. De lo contrario, use una batería marina AGM de ciclo profundo de 12 voltios y 105 amperios o más. Las baterías de celda húmeda contienen ácido y se deben tomar precauciones al manipularlas. NO USE baterías de gel o baterías automotrices.
SOLUCIÓN DE PROBLEMAS PELIGRO RIESGO DE DESCARGA ELÉCTRICA. Siempre desconecte la fuente de alimentación antes de intentar instalar, reparar o mantener la bomba. Nunca manipule una bomba con las manos mojadas o cuando esté parado sobre una superficie mojada o húmeda o en el agua. Podría producirse una descarga eléctrica mortal.
WARRANTY Este producto se garantiza por un período de tres años a partir de la fecha de compra. Sujeto a las condiciones indicadas a continuación, el fabricante se compromete a reparar o reemplazar al consumidor original cualquier parte del producto que resulte defectuosa debido a defectos de materiales o mano de obra. Para obtener el servicio de garantía, póngase en contacto con el distribuidor al que le compró el producto.