Spec Sheet

12 1/16
4 21/32
3 7/8 6 1/4
3 7/8
4
4 5/8
1-1/2 X 11-1/2 NPT
RESERVE POWERED DESIGN
For unusual conditions a reserve safety factor is en gi neered into the design of every Zoeller pump.
SK1102
MAIL TO: P.O. BOX 16347
Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road
Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP
FAX (502) 774-3624
Manufacturers of . .
www.zoeller.com
© Copyright 2010 Zoeller Co. All rights reserved.
10 20 30 40 50 60 70
80
5
10
15
20
25
0
0
80 160 240
2
4
6
GALLONS
LITERS
FLOW PER MINUTE
METERS
FEET
TOTAL DYNAMIC HEAD
PUMP PERFORMANCE CURVE
MODEL 98
98
95
170
231
273
Liters
23 ft.(7.0m)
Shut-off Head:
20 7.1 25
Meters
15
10
Feet
5
4.6
3.0
1.5
MODEL
61
72
Gal.
45
009971
All installation of controls, protection devices and wiring should be done by a
quali fied licensed electrician. All electrical and safety codes should be fol lowed
in clud ing the most recent National Electrical Code (NEC) and the Oc cu pa tional
Safety and Health Act (OSHA).
For information on additional Zoeller products refer to catalog on Piggyback Variable Level
Switches, FM0477; Electrical Alternator, FM0486; Mechanical Al ter na tor, FM0495; Sump/
Sewage Basins, FM0487; Single Phase Simplex Pump Control, FM1596; Alarm Systems,
FM0732.
SELECTION GUIDE
1. Integral oat operated mechanical switch, no external control re quired.
2. For automatic use single piggyback variable level oat switch or dou ble
pig gy back vari able level oat switch. Refer to FM0477.
3. See FM1228 for correct model of simplex control panel.
4. See FM0712 for correct model of duplex control panel or FM1663 for a
res i den tial alternator system.
98 Series Control Selection
Model Volts-Ph Mode Amps Simplex Duplex
M98 115 1 Auto 9.4 1 4
N98 115 1 Non 9.4 2 or 3 4
D98 230 1 Auto 4.7 1 4
E98 230 1 Non 4.7 2 or 3 4
CONSULT FACTORY FOR SPECIAL APPLICATIONS
Electrical alternators, for duplex systems, are available and
supplied with an alarm
Mechanical alternators, for duplex systems, are available
with or without alarm switches
Variable level oat switches are available for controlling single
and three phase systems
Double piggyback variable level oat switches are available for
variable level long cycle controls
Refer to FM1922 and FM0806 for temperatures above 130°F
OPTIONAL PUMP STAND P/N 10-2421
Reduces potential clogging by debris.
Replaces rocks or bricks under the pump.
Made of durable, noncorrosive ABS.
Raises pump 2" off bottom of basin.
Provides the ability to raise intake by adding sections of 1½"
or 2" PVC piping.
Attaches securely to pump.
Accommodates sump, dewatering and ef uent applications.
NOTE: Make sure oat is free from obstruction.
"Easy assembly"
(pump & discharge pipe
not included.)