Salt Water Installation

SHEET
1 OF 1
SCALE
APPROVED
DRAWN
CHECKED
ENGINEER
REV
-
SIZE
A
DWG NUMBER
1 : 1
STAK Enterprises, Inc.
S. Johnson
S. Johnson
TBD
09/16/10
09/16/10
Sump Pump
Discharge pipe
Sensors mounted to pipe
suspended from top
of pit. Sensor tip should
extend below end of pipe.
Recommended HC6000
Sensor Installation for
Pits With High Mineral
Content Or Water
Softener Discharge
Alternate HC6000
Sensor Installation
Why This Works:
Any wet surface is conductive in a tank
or pit. Normally this isn't a problem,
but if the pit gets water from a water
softener this water film is very conductive
and gives an alternate path to ground
(Path A) for the lower sensor. If the
sensor is mounted from a pipe
suspended from the top of the pit the
alternate path (Path B) dead ends
when it reaches the dry part of the
pipe above the upper sensor.
Path A
Path B