Specification Sheet

SECTION: 2.45.065
FM2810
0518
Supersedes
0814
TECHNICAL DATA SHEET
912 PACKAGE SYSTEMS
PREASSEMBLED SEWAGE SYSTEMS FOR FAST INSTALLATION.
PUMP SPECIFICATIONS
MOTOR
Voltage 115
Phase 1
Hertz 60
RPM 1400 or 2800
Type Split phase or permanent split capacitor
Insulation Class B
Amps 4.4 - 8.5
PUMP
Operation Automatic
Auto On / Off Varies based on package
Discharge Size 2" NPT
Solids Handling 2" (50 mm) spherical solids
Cord Length 20' (6 m) standard
Max. Head 14' (4.3 m), 22" (6.7 m), 45.6' (13.9 m)
Max. Flow Rate
92 GPM (20.9 m
3
/hr), 106 GPM (24 m
3
/hr),
149 GPM (33.8 m
3
/hr)
Max. Operating Temp. 130 °F (54 °C)
Cooling Oil lled
Motor Protection Auto reset thermal overload
MATERIALS
Cap Cast iron
Motor Housing Cast iron
Pump Housing Cast iron
Base Engineered plastic or cast iron
Upper Bearing Sleeve bearing
Lower Bearing Sleeve or ball bearing
Mechanical Seals Carbon/ceramic
Impeller Type Non-clogging vortex
Impeller Engineered plastic or bronze
Hardware Stainless steel
Motor Shaft
1215 cold rolled steel, 1144 steel or JIS
S45C steel
Gasket Neoprene
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
BASIN SPECIFICATIONS
Polyethylene basin
Polyethylene structural foam cover with 2" vent and 2" discharge
41 gallon (155 liter) capacity (25 gallons [95 liters] below inlet)
Integral foam seal
SK2694
8” (20.4 cm)
26-1/2”
(67.4 cm)
25-5/8” (66.0 cm)
28” (71.2 cm)
24" x 24" (61 x 61 cm) shown, 18" x 30" (46 x 76 cm)
and 24" x 36" (61 x 91 cm) also available.
© Copyright 2018 Zoeller
®
Co. All rights reserved.
502-778-2731 | 800-928-7867 | 3649 Cane Run Road | Louisville, KY 40211-1961 | zoellerpumps.com
These systems are not designed
for hazardous environments. Please consult
factory for special options and requirements.

Summary of content (4 pages)