User Guide
1
INSTALLATION INSTRUCTIONS
PREINSTALLATION CHECKLIST
SECTION: 6.10.044
FM2116
0703
Supersedes
0503
Notice to Installer: Leave instructions with homeowner.
1. Inspect your unit. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using.
DO NOT remove the test plugs from the pump.
2. Carefully read the literature provided to familiarize yourself with specic details regarding installation and use. These materials
should be retained for future reference.
1. To reduce the risk of electrical shock, a properly grounded
receptacle of grounding type must be installed and protected
by a ground fault circuit interrupter (GFCI) and in accordance
with National Electrical Code and local codes.
(SEE WARNING BELOW)
2. Make certain that the receptacle is within the reach of the pump’s
power supply cord. DO NOT USE AN EXTENSION CORD.
Extension cords that are too long or too light do not deliver
sufcient voltage to the pump motor. But more important, they
could present a safety hazard if the insulation were to become
damaged.
3. Testing for Ground. As a safety measure, each electrical outlet
should be checked for ground using an Underwriters Laboratory
Listed circuit analyzer which will indicate if the power, neutral
and ground wires are correctly connected to your outlet. If they
are not, call a qualied electrician.
4. For Added Safety. Pump must be connected to a 3-prong
grounded outlet interrupter device (ground fault circuit inter-
rupter).
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP
FROM ITS POWER SOURCE BEFORE HANDLING. Single
phase pumps are supplied with a 3-prong grounded plug to help
protect you against the possibility of electrical shock. DO NOT,
UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND
PIN. To reduce the risk of electrical shock, a properly grounded
receptacle of grounding type must be installed and protected
by a ground fault circuit interrupter (GFCI) in accordance with
national electrical code and local codes.
6. Installation and checking of electrical circuits and hardware
should only be performed by a qualied licensed electrician.
7. Risk of electric shock - These pumps have not been investi-
gated for use in swimming pool areas.
8.
According to the state of California (Prop. 65), this product contains
chemicals known to the state of California to cause cancer and
birth defects or other reproductive harm.
1. Check to be sure your power source is adequate for handling
the voltage requirements of the motor, as indicated on the pump
or basin plate.
2. Make sure the pump electrical supply circuit is equipped with
fuses or circuit breakers of proper capacity. A separate branch
circuit is recommended, sized according to the National Electri-
cal Code for the current shown on the pump name plate.
3. All plumbing (discharge and vent lines) must be installed to meet
local codes. Unit must be vented. DO NOT USE AN AUTOMATIC
PLUMBING VENT DEVICE SIMILAR TO A “PRO-VENT”.
Some states require this product to be installed by a licensed
plumber.
4. Repair and service should be performed by Zoeller Pump
Company Authorized Service Station only.
5. CHECK VALVE MUST BE USED TO REDUCE UNNECESSARY
CYCLING OF PUMP.
6. This system must be installed above the water table. Ground-
water outside the basin will cause it to collapse.
SEE BELOW FOR LIST OF WARNINGS
CAUTION
SEE BELOW FOR LIST OF CAUTIONS
MODEL:_______________________
DATE CODE: __________________
DATE INSTALLED: _____________
PREASSEMBLED/JOB READY
OUTDOOR SEWAGE SYSTEMS
MODELS 912-0082, 912-1082, 912-0083, 912-1083,
912-0084, 912-1084, 912-0085 & 912-1085
© Copyright 2003 Zoeller Co. All rights reserved.
NOTE: Pumps with the “UL” mark and pumps with the “US” mark
are tested to UL Standard UL778. CSA Certied pumps are
certied to CSA Standard C22.2 No. 108.
Product information presented
here reects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.